Revolabs 03-HDEXEC4EU 03-HDEXECCN, 03-HDEXECEU, 03-HDEXEC4CN, 01-HDEXEC4 Controls and Connections

Page 8

Controls and Connections:

1.Channel LED indicators: Displays microphone mute and pairing states.

2.Diversity Antenna: One or two sets (4 channel or 8 channel).

3.Pairing Push Buttons: For pairing microphones to Base Station.

4.Two Line LCD Display for front panel operation, command and control.

5.Navigation Buttons for menus on front panel LCD interface. (See Section Using the Base Station Front Panel Display)

6.On/Off Switch: Powers up unit.

7.Power In Receptacle (100-240 VAC).

8.Ethernet Port

9.System Reset Button

10.Mini-Phoenix Connector: Multiple Base Station (BUS) synchronization connection.

11.RS-232 Serial Interface, DB9 (see Section Using the Serial Control Processor (RS232 or IP)

12.Base station status LED‘s (see Section Revolabs Executive HD ™ Indicator LEDs)

13.Configuration DIP Switches (see Section Using the Rear Panel Configuration DIP switches)

14.Mini-Phoenix Connectors: Balanced Audio in and out connections (4 or 8 channels, in and out).

The Revolabs Executive HD ™ Base Station is designed to be installed into a standard 19‖ AV rack using the attached rack ears.

To Install the Base Station:

1.Plug the power cord into an appropriate outlet.

2.Turn the fuse-protected power switch on the back panel to ―RESET‖. The LCD on the front panel will illuminate.

3.Attach the diversity antennas (2 or 4 SMA female connectors).

- 8 -

Image 8
Contents Revolabs Executive HD Page Contents Safety and General Information FCC Notice to UsersStandards to which Conformity is declared Introduction System ComponentsInstalling the Revolabs Executive HD Base Station Controls and Connections Revolabs Executive HD Audio Connections Configuring the Executive Hdtm Base StationUsing Multiple Revolabs Executive Hdtm Systems Together Primary DIP#1 -off Secondary DIP#1 -on Wire BUS cable Revolabs HD Gold Control Panel Using the Rear Panel Configuration DIP SwitchesUsing the Revolabs HD Control Panel Software System Scan Network Configuration SettingsFile Record Events System Set Box Name System Set Telnet PasswordSystem Set IP Configuration System Enable Gold Firmware Update FirmwareConfig External Control Processor Tools Express PairConfig Audio Mode Config RedundancyConfig Power Scaling Config Transmit PowerStatus Monitoring Config Lock Front PanelConfig Audio Zone Monitor Microphone Version Monitor Microphone BatteryMonitor Microphone Type Using the Serial Control Processor RS-232 or IP Monitor DIP SwitchesUsing the Executive HD Base Station with a Control System Monitor VersionsSerial Command & Return Strings String TablePage Using the Executive HD Base Station with a DSP Channel #Examples ClearOne Converge & XAPBiamp Audia & Nexia MUTE4Polycom SoundStructure Using the Base Station Front Panel Display Using the HD Wearable Wireless Microphones Revolabs HD Microphones and HD Microphone AdaptersAdjusting the Volume on the Wearable Microphone Earpiece Pattern 360 ºPickup Acoustic Cover protects microphone element non-removable Using the HD XLR Microphone Wireless Adapter Using the HD Wireless Adapter for Countryman Microphone Pairing Wireless Microphones to Base Station Revolabs Executive HD Charger Base Power Module Updating the Revolabs Hdtm FirmwareCharging the Microphone Batteries Updating the Executive HD Base Station & MicrophonesPage Revolabs Executive HD Indicator LEDs GreenWarranty Specifications Dimensions, L, W, H and WeightMaximum Audio Channels Power Cord Receptacle LED indicatorIndex Charger Bays