Revolabs Executive HD™ Audio Connections

There are (8) 3.5mm mini-Phoenix inputs and (8) 3.5mm mini-Phoenix outputs on the back panel of the unit (four on the 4-channel system) providing access to each channel‘s audio signal.

The provided mini-Phoenix connectors are designed for easy wiring. The three terminals (from left to right) correspond to positive +, negative -, and shielded ground .

To connect audio In/Out on the Base Station

1.Use the screws on top of the connector to first loosen the terminals.

2.Insert an appropriate 3-conductor cable (2 conductors and shield) into the terminals.

3.Tighten the screw to secure the cable.

4.Push the connector onto the pins centered under the desired input or output port until firmly secured.

The microphone output connectors need to be attached to the line-level (0dBu) input connectors of an audio mixer. PHANTOM POWER MUST BE OFF. PHANTOM MAY CAUSE DAMAGE TO THE BASE STATION.

The Base Station input connectors (also 0dBu) may then be attached to mixer channel outputs. Because the system is full-duplex, the input connections provide the ability to hear program audio using a 2.5mm earpiece attached to the microphone (supplied with the wearable microphone).

Depending on the application, it is possible to feed a single mixed channel back to all earpieces or, alternatively, each user can receive a separate and unique channel. This would allow for translation, personal hearing assistance or other services to be incorporated into an application.

Configuring the Executive HDTM Base Station

Each Revolabs Executive HDTM Base Station must be configured properly prior to use. Accurate configuration is dependent on several variables such as:

1.How many Executive HDTM systems are being used together in proximity?

2.What type of 3rd party mute control is being used?

3.How large is the room?

4.Is Line Level or Mic Level signal required?

5.How do the mic mutes need to function?

Once these questions are answered, accurate configuration of the Executive HD base can be achieved using a combination of the following methods.

Using Multiple Revolabs Executive HDTM Systems Together

If more than one Revolabs Executive HD ™ Base Station is used in an area, each unit needs to be interconnected with a synchronization (BUS) cable using a standard 3.5mm mini-Phoenix connector and any 26AWG or better, shielded cable. The maximum distance from the Primary unit to any Secondary device must not exceed 300‘ (90 meters). In addition, DIP switch #1 needs to be adjusted on one or more of the units to represent the ‗Primary‘ and ‗Secondary‘ devices.

- 9 -

Image 9
Contents Revolabs Executive HD Page Contents FCC Notice to Users Safety and General InformationStandards to which Conformity is declared System Components IntroductionInstalling the Revolabs Executive HD Base Station Controls and Connections Configuring the Executive Hdtm Base Station Using Multiple Revolabs Executive Hdtm Systems TogetherRevolabs Executive HD Audio Connections Primary DIP#1 -off Secondary DIP#1 -on Wire BUS cable Using the Rear Panel Configuration DIP Switches Using the Revolabs HD Control Panel SoftwareRevolabs HD Gold Control Panel Configuration Settings File Record EventsSystem Scan Network System Set Telnet Password System Set IP ConfigurationSystem Set Box Name Firmware Update Firmware System Enable GoldConfig External Control Processor Tools Express PairConfig Redundancy Config Audio ModeConfig Power Scaling Config Transmit PowerConfig Lock Front Panel Config Audio ZoneStatus Monitoring Monitor Microphone Battery Monitor Microphone TypeMonitor Microphone Version Monitor DIP Switches Using the Serial Control Processor RS-232 or IPUsing the Executive HD Base Station with a Control System Monitor VersionsString Table Serial Command & Return StringsPage Channel # Using the Executive HD Base Station with a DSPExamples ClearOne Converge & XAPMUTE4 Biamp Audia & NexiaPolycom SoundStructure Using the Base Station Front Panel Display Revolabs HD Microphones and HD Microphone Adapters Using the HD Wearable Wireless MicrophonesAdjusting the Volume on the Wearable Microphone Earpiece 360 º PickupPattern Acoustic Cover protects microphone element non-removable Using the HD XLR Microphone Wireless Adapter Using the HD Wireless Adapter for Countryman Microphone Pairing Wireless Microphones to Base Station Revolabs Executive HD Charger Base Updating the Revolabs Hdtm Firmware Power ModuleCharging the Microphone Batteries Updating the Executive HD Base Station & MicrophonesPage Green Revolabs Executive HD Indicator LEDsWarranty Dimensions, L, W, H and Weight SpecificationsMaximum Audio Channels LED indicator Power Cord ReceptacleIndex Charger Bays