Revolabs 03-HDEXECEU, 01-HDEXEC4 Primary DIP#1 -off Secondary DIP#1 -on Wire BUS cable

Page 10

The three terminals of the BUS connector should be wired in parallel via either a daisy chain connection or terminal block split. The three contacts of the phoenix connector are as follows from left to right.

1.Sync

2.Master Mute

3.Ground

Set one Base Station as the Primary device by putting DIP switch #1 to the ‗Off‘ position. The other units must be set as Secondary devices by putting DIP switch #1 to the ‗On‘ position. In this configuration, the Primary device manages the entire system, distributing microphone transmission across available channels to maintain frequency integrity, and coordinating system muting.

Primary (DIP switch 1, Off – default): This designates the Base Station as the master control unit.

Secondary (DIP switch 1, On): Additional base stations to be used in the same area must be connected via the BUS and be set to REMOTE mode to ensure synchronization of timing clocks between bases in order to prevent interference.

Primary (DIP#1 –off)

Secondary (DIP#1 –on)

Secondary (DIP#1 –on)

3-wire BUS cable

Note: Whenever a DIP switch is toggled, the base unit should be reset, or the power should be cycled for the switch setting to be registered.

Warning: The switch must be in the „Primary‟ position for a single Base Station system, which is the factory default setting. Microphones will not function if the switch is in the „Secondary‟ position and no „Bus‟ cable is connected.

The maximum number of microphone channels within a 300‘ (90 meter) radius in the Americas or Japan is 16 channels (High Definition mode) or 32 channels (Max Density mode). The maximum number of channels within a 300‘ (90 meter) radius for a EU or CN frequency system is 24 channels (High Definition mode) or 40 channels (Max Density mode). (See Section Using the Revolabs HD Control Panel Software)

Note: Using Revolabs Executive HD systems in the same area(s) without the bases connected via the BUS will result in interference

Warning: Using the maximum number of Revolabs HD Microphones in a given will occupy 100% of the available RF bandwidth. Any other wireless device operating in the same frequency could cause significant interference with the Revolabs HD Microphones. It is recommended that no other DECT or DECT 6.0 products be used within operational range of the Executive HD system(s).

- 10 -

Image 10
Contents Revolabs Executive HD Page Contents Safety and General Information FCC Notice to UsersStandards to which Conformity is declared Introduction System Components Installing the Revolabs Executive HD Base Station Controls and Connections Using Multiple Revolabs Executive Hdtm Systems Together Configuring the Executive Hdtm Base StationRevolabs Executive HD Audio Connections Primary DIP#1 -off Secondary DIP#1 -on Wire BUS cable Using the Revolabs HD Control Panel Software Using the Rear Panel Configuration DIP SwitchesRevolabs HD Gold Control Panel File Record Events Configuration SettingsSystem Scan Network System Set IP Configuration System Set Telnet PasswordSystem Set Box Name Config External Control Processor System Enable GoldFirmware Update Firmware Tools Express PairConfig Power Scaling Config Audio ModeConfig Redundancy Config Transmit PowerConfig Audio Zone Config Lock Front PanelStatus Monitoring Monitor Microphone Type Monitor Microphone BatteryMonitor Microphone Version Using the Executive HD Base Station with a Control System Using the Serial Control Processor RS-232 or IPMonitor DIP Switches Monitor VersionsSerial Command & Return Strings String TablePage Examples Using the Executive HD Base Station with a DSPChannel # ClearOne Converge & XAPBiamp Audia & Nexia MUTE4Polycom SoundStructure Using the Base Station Front Panel Display Using the HD Wearable Wireless Microphones Revolabs HD Microphones and HD Microphone AdaptersAdjusting the Volume on the Wearable Microphone Earpiece Pickup 360 ºPattern Acoustic Cover protects microphone element non-removable Using the HD XLR Microphone Wireless Adapter Using the HD Wireless Adapter for Countryman Microphone Pairing Wireless Microphones to Base Station Revolabs Executive HD Charger Base Charging the Microphone Batteries Power ModuleUpdating the Revolabs Hdtm Firmware Updating the Executive HD Base Station & MicrophonesPage Revolabs Executive HD Indicator LEDs GreenWarranty Specifications Dimensions, L, W, H and WeightMaximum Audio Channels Index Power Cord ReceptacleLED indicator Charger Bays