Common Tops log messages (0200)

DNC Logs 9

0001/000A Message: [PRU_name] encountered a segment or mapper error. This is an unrecoverable error and the PRU should be rebooted. If rebooting the PRU does not solve the problem, reboot the SRU.

Description: The software task failed because it encountered a segment or mapping error. The PRU may declare itself faulty or recreate the task. If the PRU declares itself faulty then the log subsystem detects the faulty condition and raises an alarm.

Action: Reboot the PRU. If this action does not correct the problem, then reboot the SRU. If the error occurs more than once a week replace the SRU. Document the problem and record all action taken.

0001/000B Message: [PRU_name] has been in a critical region too long. This is an

unrecoverable error and the PRU should be rebooted.

Description: The software task failed due to a software error. The PRU may declare itself faulty or recreate the task. If the PRU declares itself faulty then the log subsystem detects the faulty condition and raises an alarm.

Action: If the PRU is in the working state, no action is required. If the PRU is in the faulty state, document the problem, restart the PRU, and then contact NT.

0001/000C Message: [PRU_name] has encountered a parity error. This is an unrecoverable error and the SRU should have diagnostics run.

Description: The software task failed because of a parity error. The PRU may declare itself faulty or recreate the task. If the PRU declares itself faulty then the log subsystem detects the faulty condition and raises an alarm.

Action: Run diagnostics on the SRU containing the PRU. To do this take all other PRUs out of service first. If diagnostics fail, replace the SRU. If diagnostics do not detect an error but the problem persists, replace the SRU. Document the problem and record all action taken.

0001/000D Message: [PRU_name] encountered a kernel error. This is an unrecoverable error and the SRU should be rebooted.

Description: The software task failed because the kernel of the SRU in which the PRU is operating has encountered an unexpected state. The PRU may declare itself faulty or recreate the task. If the PRU declares itself faulty then the log subsystem detects the faulty condition and raises an alarm.

Action: Reboot the SRU. If the error occurs more than once a week replace the SRU. Document the problem and record all action taken.

0001/000E Message: [PRU_name] has encountered a floating point math error. This is an unrecoverable error and the PRU should be rebooted.

Description: The software task failed due to a reference error. The PRU may declare itself faulty or recreate the task.

Action: If the PRU is in the working state, no action is required. If the PRU is in the faulty state, document the problem, restart the PRU, and then contact NT.

TOPS VSN Log and alarm messages

Image 15
Contents Tops Voice service nodePage Tops VSN log and alarm messages Page Contents Page Introduction Sample Tops VSN log/alarm messageMajor GErrorLError CriticalNumber Type InformationChange history Tops VSN log messages DNC Logs Tops VSN Log Messages Common Tops VSN log messages Common Tops VSN log messages Common Tops log messages DNC Logs Common Tops VSN log messages Common Tops log messages DNC Logs Page Common Tops VSN log messages Common Tops VSN log messages Common Tops log messages DNC Logs Common Tops VSN log messages Common Tops log messages DNC Logs Common Tops VSN log messages Common Tops VSN log messages Common Tops VSN log messages Common Tops log messages DNC Logs Common Tops VSN log messages Common Tops log messages DNC Logs Common Tops VSN log messages Common Tops log messages DNC Logs Common Tops VSN log messages Common Tops log messages DNC Logs Common Tops VSN log messages Common Tops log messages DNC Logs Common Tops VSN log messages Common Tops log messages DNC Logs Common Tops VSN log messages Common Tops log messages DNC Logs Common Tops VSN log messages Common Tops log messages DNC Logs Common Tops VSN log messages Common Tops log messages DNC Logs Common Tops VSN log messages Common Tops VSN log messages Page Common Tops VSN log messages 020A Common Tops VSN log messages 020A Common Tops log messages 020A DNC Logs Common Tops VSN log messages 020A Common Tops log messages 020A DNC Logs Common Tops VSN log messages 020A Common Tops VSN log messages Page Voice interface resource manager log messages Page User 3 Input Alarm SubsystemAlarm Subsystem Acpe resource manager log messages Acpe Resource Manager Log Messages Acpe Resource Manager Log Messages 9440 Acpe Resource Manager Log Messages Control link log messages Control Link Log Messages Application call processing engine log messages Application Call Processing Engine Log Messages Application Call Processing Engine Log Messages 9442 Application Call Processing Engine Log Messages Application Call Processing Engine Log Messages 9442 Message 14. T1 resource manager log messages 66 T1 Resource Manager Log Messages Action T1 Resource Manager Log Messages 9443Page Action None Locality database log messages 944ELocality Database Log Messages 944E Second string gives additional information on the problem Page Acpe Maintenance Position log messages Page Prompt manager log messages Description Prompt Manager Log MessagesSuppressed Logs Suppressed and Thresholded Logs78 3. Suppressed and Thresholded Logs Could not Send NotificationSuppressed and Thresholded Logs Cleaning UP of Alarms80 3. Suppressed and Thresholded Logs DMS notices VsnalarmPage List of abbreviations used in this Publication follows AbbreviationsTops