AMX NXC-M/ME/MPE, NXM-MHS NXC-M Master Card Specifications, Rear Panel Components

Page 13
NXC-M Master Card

NXC-M Master Card

NXC-M Master Card

Specifications

NXC-M Master Card Specifications

Power Requirements

260 mA @ 12 VDC

 

 

Memory

• Disk on chip (Non-volatile): 8 MB (upgradeable to 32 MB)

 

• SDRAM (Volatile): 16 MB

 

• NVS (Non-volatile): 1 MB

 

 

Front Panel Components:

 

Connector

Program port - DB-9 (male) connector for system programming and diagnos-

 

tics

LED indicators

• Status - Green LED shows AXlink/NetLink data activity.

 

• Output - Red LED shows data output activity.

 

• Input - Yellow LED shows data input activity.

 

 

Rear Panel Components

 

LED indicators

• AXlink - Green LED blinks to show AXlink data activity.

 

• ICSNet - Green LEDs that light when sending/receiving data.

 

• ICSHub IN/OUT - Yellow LEDs that light when sending/ receiving data.

Connectors

• PWR - 2-pin (male) green captive-wire connector for 12 VDC power.

 

• AXlink - Black 4-pin (male) captive-wire connector that provides data and

 

power to external control devices.

 

Power rating = 6 A max; actual load depends on connected power supply.

 

• PROGRAM port - 5-pin (male) gray connector for system programming and

 

diagnostics.

 

• ICSNet - Two RJ-45 connectors that provide power and data to external

 

ICSNet devices.

 

Power rating = 500 mA.

 

• ICSHub IN/OUT - Two RJ-45 connectors that provide data to other Hubs

 

connected to the Master Card.

 

 

Enclosure

Metal with black matte finish.

 

 

Front Faceplate

Plastic gray with translucent viewing window.

 

 

Dimensions (HWD):

 

Card(s)

0.5" x 4.8" x 8.5" (127 mm x 121.9 mm x 215.9 mm)

Module

1.5" x 5.0" x 8.8" (45 mm x 127 mm x 224 mm)

 

 

Weight:

 

Card only

11.2 oz (317.51 g)

With module

12.8 oz (362.87 g)

 

 

Optional accessories

• 12 VDC power supply (PSN 6.5, PSN 2.8)

 

AC-RK Accessory Rack Kit (Module)

 

 

NetLinx Master Cards and Modules

7

 

 

 

 

Image 13
Contents instruction manual NetLinx Master Cards and ModulesNXM-MHS, NXC-M/ME/MPE NetLinx Central Controllers and CardsAMX Limited Warranty and Disclaimer Installation and Wiring Table of ContentsProduct Information - NetLinx Modules NXC-M Master CardNetLinx Security ProgrammingProgram Port Commands NetLinx Security FeaturesSetup Security Default Security ConfigurationMain Security Menu Logging Into a SessionNetLinx Master Cards and Modules NXM-MHS NXM Modules Product Information - NetLinx ModulesNXM-MHS specifications NXM-MHS SpecificationsProgram Port DIP switch - baud rate settings NXM-MHS Specifications ContProgram Port DIP switch - Program Run Disable PRD mode Baud Rate SettingsPRD Mode Settings Setting the Program Port DIP SwitchDB-9 Program Port, Pinouts, and Signals Program Port Connections/Wiring5-Pin Program Port Pinouts and Signals DB-9 Program port front panelModes and LED Blink Patterns Modes and front panel LED blink patternsRear panel LEDs ICSNet/ICSHub Rear panel LEDs AXLinkRear panel LEDs Ethernet ME and MPE only NXC-M Master Card SpecificationsNXC-M Master Card Specifications NXC-M Master CardRear panel components Installing an optional NCP-E Ethernet Card3. Mount the NCP-E to the NXC-M, as shown in FIG NetLinx Master Cards and Modules NXC-ME Specifications NXC-ME Master-Ethernet CardNXC-ME Master-Ethernet Card Ethernet Ports used by the ME Ethernet Ports used by the MEPort Type Standard Port #NXC-MPE Specifications NXC-MPE Master Port Expander CardNXC-MPE Master Port Expander Card Ethernet 10/100 LEDs Ethernet 10/100 connector SPE Port Connection/WiringICSNet connectors/LEDs ICSHub In/Out connectors/LEDs FIG. 9 NXC-MPE Card shown mounted in a NXS-MHS Module - rear viewSPE Cable pinout information SPE Connector Pinouts and SignalsNetLinx Master Cards and Modules Mounting the Modules Into an Equipment Rack Installation and WiringMounting the Master Cards in an NXF CardFrame or NXI Preparing/connecting captive wires ICSNet RJ-45 Connections/WiringICSNet RJ-45 Pinouts/Signals Ethernet 10/100 Base-T RJ-45 Connections/Wiring ICSHub RJ-45 Connections/WiringISCHub Pinouts and Signals Ethernet RJ-45 Pinouts and SignalsReplacing the Lithium Batteries Programming Program Port CommandsPC COM Port Communication Settings Program Port CommandsProgram Port Commands Cont SET TIME Notes on specific Telnet/Terminal clients ESC Pass CodesESC Pass Codes Windows client programsNetLinx Security NetLinx Security FeaturesSecurity Terms Used in This Document NetLinx Security FeaturesAccess Rights PasswordUser Name Group NameAccessing the Security configuration options Initial Setup via Telnet or Terminal connectionGetting connected If NetLinx master security is not enabled, you will see the following 2 Display system security options for NetLinx master Security Options Menu3 Add user Edit User Menu 4 Edit UserAccess Rights Menu Access Rights MenuEdit User Menu 5 Delete user Access Rights Menu Cont6 Show the list of authorized users 7 Add GroupEdit Group menu Delete directory association Edit Group Menu Add directory associationEdit Group menu Display Access Rights Edit Group menu Change Access RightsEdit Group menu List directory associations 8 Edit Group12 Display Telnet Timeout in seconds 11 Set Telnet Timeout in seconds9 Delete Group 10 Show List of Authorized GroupsMain Security Menu Main Security MenuMain Security Menu Cont Default Security ConfigurationSecurity Help Menu Options Security Help menuSecurity Help Menu Options Cont Logging Into a SessionSetup Security LogoutHelp Security NetLinx Master Cards and Modules Panja Inc to alter specificationsAMX logo AMX reserves