Agilent Technologies E2251A user manual E2261A Quad RS-232 Interface Wiring Information

Page 28

E2261A Quad RS-232 Interface Wiring Information

Serial Port 1 Serial Port 2

Serial Port 3 Serial Port 4

{

{

{

{

 

 

 

 

 

 

 

 

 

 

 

 

HP E2261A Quad Serial M-Module

Port 1

Port 2

Port 3

Port 4

 

9-Pin Connector

 

 

 

Pin Name and Function

Pin #s

Pin #s

Pin #s

Pin #s

 

Pin #

 

 

 

 

 

 

 

 

 

 

 

 

 

DTR

 

Data Terminal Ready

1

5

9

13

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

TD

 

Transmitted Data

2

6

10

14

 

3

 

 

 

 

 

 

 

 

 

 

 

 

 

RD

 

Received Data

3

7

11

15

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

RTS

 

Request to Send

16

20

24

28

 

7

 

 

 

 

 

 

 

 

 

 

 

 

 

CTS

 

Clear to Send

17

21

25

29

 

8

 

 

 

 

 

 

 

 

 

 

 

 

 

DSR

 

Data Set Ready

18

22

26

30

 

6

 

 

 

 

 

 

 

 

 

 

 

 

 

SG

 

Signal Ground

 

4, 8, 12, 19, 23, 27

 

 

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Chassis Connectiona

 

31, 32, 33, . . . 43, 44

 

 

-

 

 

 

 

 

 

 

 

 

 

 

 

a. If you use a shielded cable, connect the shield to a chassis connector pin on the 44-pin connector. Do not connect the other end of the shield.

Note: If you use the optional E2261-61601 cable, you must remove the cable hood if you install the E2261A in either of the two internal slots of the E2251A Carrier. The figure on the next page shows the cable wiring for making your own cable.

26

Image 28
Contents E2251-90002 Page Contents Contents Agilent Technologies Warranty Statement Documentation History Page Declaration of Conformity Page Page Module Installation Remove the Carrier Shields Determine M-Module Layout Set the Logical Address for each M-Module Guidelines for Determining Logical AddressesModule M3 Module M2 Module M1 Install M-Modules onto the Carrier Connect Field Wiring to Slot M4 & M5 M-Modules Reattach the Carrier Shields Install Carrier into C-Size VXI Mainframe Connect Field Wiring to Front M-Modules Installation / Operational Verification Removing M-Modules from the Carrier Module Field Wiring Information Assembling the M-Module Field Wiring ConnectorPage Place connector Connector screws on bottom shell E2259A Double-Wide Breadboard M-Module Wiring Information E2259A J102 Pinout Table E2261A Quad RS-232 Interface Wiring Information Serial Port 1 Serial Port Serial Port 3 Serial PortPage E2270A 16-Channel Form a Switch Wiring Information E2271A 4x4 Matrix Switch Wiring Information ROW2LOChannel Configuring the E2272A E2273A 8-Channel Form C Switch Wiring Information E2274A 4-Channel Power Relay Wiring Information E2290A 16-Bit Digital I/O Wiring Information UseE2291A 16-Channel Isolated Digital Output Wiring Information Page Index NumericsPosition in Carrier, 11 removing from Carrier, 20 slots