Agilent Technologies E2251A user manual

Page 7

WARNINGS (contd.)

In a cleanroom environment, some switch modules (such as the E2270A, 2271A, 2273A, etc) are capable of switching voltages that could cause bodily injury or death to an operator. Special precautions must be adhered to (discussed below) when applying voltages in excess of 60Vdc, 30Vac rms, or 42.4 Vac peak for a continuous, complex waveform.

Module connectors and test signal cables connected to them must be made NON-accessible to an operator who has not been told to access them: It is a supervisor’s responsibility to advise an operator that dangerous voltages exist when the operator is instructed to access connectors and cables carrying these voltages. Making cables and connectors that carry hazardous voltages inaccessible is a protective measure keeping an operator from inadvertant or unknowing contact with these harmful voltages. Cables and connectors are considered inaccessible if a tool (e.g., screwdriver, wrench, socket, etc.) or a key (equipment in a locked cabinet) is required to gain access to them. Additionally, the operator cannot have access to a conductive surface connected to any cable conductor (High, Low, or Guard).

Assure the equipment under test has adequate insulation between the cable connections and any operator-accessible parts (doors, covers, panels, shields, cases, cabinets, etc.): Verify there are multiple and sufficient protective means (rated for the voltages you are applying) to assure the operator will NOT come into contact with any energized conductor even if one of the protective means fails to work as intended. For example, the inner side of a case, cabinet, door, cover, or panel can be covered with an insulating material as well as routing the test cables to the module’s front panel connectors through non-conductive, flexible conduit such as that used in electrical power distribution.

5

Image 7
Contents E2251-90002 Page Contents Contents Agilent Technologies Warranty Statement Documentation History Page Declaration of Conformity Page Page Module Installation Remove the Carrier Shields Determine M-Module Layout Guidelines for Determining Logical Addresses Set the Logical Address for each M-ModuleModule M3 Module M2 Module M1 Install M-Modules onto the Carrier Connect Field Wiring to Slot M4 & M5 M-Modules Reattach the Carrier Shields Install Carrier into C-Size VXI Mainframe Connect Field Wiring to Front M-Modules Installation / Operational Verification Removing M-Modules from the Carrier Assembling the M-Module Field Wiring Connector Module Field Wiring InformationPage Place connector Connector screws on bottom shell E2259A Double-Wide Breadboard M-Module Wiring Information E2259A J102 Pinout Table Serial Port 1 Serial Port Serial Port 3 Serial Port E2261A Quad RS-232 Interface Wiring InformationPage E2270A 16-Channel Form a Switch Wiring Information ROW2LO E2271A 4x4 Matrix Switch Wiring InformationChannel Configuring the E2272A E2273A 8-Channel Form C Switch Wiring Information E2274A 4-Channel Power Relay Wiring Information Use E2290A 16-Bit Digital I/O Wiring InformationE2291A 16-Channel Isolated Digital Output Wiring Information Page Numerics IndexPosition in Carrier, 11 removing from Carrier, 20 slots