Monessen Hearth BWBC400I, BWB400I manual Trim Installation, From Opening

Page 26

GAS APPLIANCE INSTALLATION

FIGURE 28

OUTER FIREPLACE WRAP

INNER FIREPLACE WRAP

SIDE BRICK

26" MAX.

FIREPLACE FIREBOX

HEARTH BRICK

GAS LINE ACCESS TUBE

GAS LINE PLUMBING DETAIL

BACK

REFRACTORY

BRICK

MAINTAIN 1/2" MINIMUM

AIR SPACE CLEARENCE

TO COMBUSTIBLES FOR

GAS LINE OUT TO 4" FROM

SIDE OF THE FIREPLACE.

COMBUSTIBLE MATERIALS

MAY BE LOCATED AT ZERO

CLEARANCE TO GAS LINEKNOCKOUT BEYOND 4" FROM FIREPLACE

SIDE.

SIDE

REFRACTORY

BRICK

CAUTION: WHEN USING A GAS APPLIANCE, THE FIREPLACE DAMPER MUST BE SET IN FULLY OPEN POSITION.

REPACK INSULATION AROUND

GAS LINE WHERE IT PASSES THRU GAS LINE ACCESS TUBE FOR

PROPER SEAL.

FIGURES 29 AND 30 SHOW ACCEPTABLE COMBUSTIBE MANTEL LOCATIONS IF AN UNVENTED GAS APPLIANCE IS INSTALLED IN THE FIREPLACE. SEE PART C OF FIGURE 31 FOR ACCEPTABLE COMBUSTIBLE MANTEL LOCATION IF FIREPLACE IS INSTALLED TO BURN WOOD.

COMBUSTIBLE

FIGURE 29

FIGURE 30

COMBUSTIBLE

8"

MANTEL AND/OR

 

FRAMING

 

 

TRIM MAY BE

 

MEMBERS

 

 

 

 

 

PLACED WITHIN

 

MAY BE

12" MAX.

 

 

 

THE SHADED AREA.

 

PLACED

 

 

 

 

ACROSS

 

 

NON-COMBUSTIBLE

 

TOP SPACERS.

 

 

WALLBOARD

1 1/2"

 

 

 

 

 

 

 

 

MAX.

 

12"

 

 

 

2 3/4" HOOD

NOTE: NO COMBUSTIBLE

 

 

 

(PART NO.

MATERIAL BELOW 12"

 

 

48"

075629)

FROM OPENING

TOP "V"

(MIN.)

 

39 1/2"

SPACERS

 

44"

 

075629 HOOD MUST

 

 

 

BE INSTALLED WHEN

 

 

(MIN.)

 

MANTEL IS 12" FROM

 

 

 

 

FIREPLACE OPENING.

 

 

 

 

WHEN 075629 HOOD IS

 

 

 

 

INSTALLED GLASS DOORS

 

 

 

 

HAVE TO BE REMOVED.

 

 

 

SIDE VIEW CUT-AWAY

 

FLOOR

 

 

 

 

FACING AND MANTEL CONSTRUCTION

 

USE ONLY NON-COMBUSTIBLE MATERIALS BELOW

 

 

 

 

 

 

TOP OF SPACERS AND BEHIND FRONT FACE.

TRIM INSTALLATION

Do not allow the trim materials to extend closer than 3/8 inch to the vertical edges of the firebox opening if you plan to equip the fireplace with glass doors.

The face of your fireplace may be left exposed or trimmed. If trim is installed, be sure it is fastened securely to the face of the fireplace. Any crack between the trim material and the face of the fireplace could pose a fire hazard and impair the proper operation of the fireplace; seal such cracks. See Figure 31. Blocking the fireplace with framing and attaching the base to the supporting floor will reduce the possibility of a crack redeveloping after sealing. (CAUTION: ACCEPTABLE COMBUSTIBLE MANTEL LOCATION SHOWN BY PART C OF

FIGURE 31 IS FOR WOODBURNING FIREPLACE INSTALLATION ONLY. SEE FIGURES 29 AND 30 FOR ACCEPTABLE COMBUSTIBLE MANTEL LOCATIONS WHEN AN UNVENTED GAS APPLIANCE IS INSTALLED IN THE FIREPLACE.)

26

53D9031. Rev 1 03/03

Image 26
Contents BWB400-SERIES SeriesTable of Contents Important Information Operation Guidelines Residential Installation ClearancesOutside AIR Connector Centerline Fireplace Location Installation Preparation Single Story Installation with Attic Space Floor Protection Fireplace MIN Floor Line with Raised Hearth Fireplace Components See for Illustration of Fireplace Components Described below Fireplace Installation Chimney Installation 17 x Chimney Offset Installation Chimney Offset and CAP Installation SF30 Firestop SpacerChimney CAP Installation Chimney Height and Offset Charts Intermediate Height Sections InchesChimney CAP Chase Installation Outside Combustion AIR Precautions and Recommendations Outside Combustion AIR Precautions & Recommendations Basement InstallationCombustion AIR Assembly GAS Appliance InstallationGAS Appliance Installation Trim Installation From OpeningPart a Glass Door Installation and FAN Accessory Fireplace Operation Species Density Heat Value Maintenance and Safety DO’S DONT’S Parts Diagram and List Model FireplaceBWBC400/BWBC400I Limited Warranty Except BlowersYour Duties This page intentionally left blank 53D9031. Rev 1 03/03 Appliance Installer BWB500, BWB500I, BWBC500 Congratulations Intended Product Usage Operation Guidelines Residential Installation Framing Corner Installation Side Wall Installation Joist Insulate Same Single Story Installation with Attic Space Brick or Stone Hearth Floor Line with Raised Hearth Fireplace Metal Safety Strip SCS Model Description Fireplace Installation Chimney Installation 17 x Although Both Halves 14-1/2 Chimney CAP Installation Straight RUN Chimney Sections Intermediate Height Inches Chimney CAP Chase Installation Outside Combustion AIR Precautions & Recommendations Outside Combustion AIR Recommendations Model AK4 Combustion AIR Assembly GAS Appliance Installation Applying Decorative Trim to the Fireplace Outline Fireplace Firebrick FAN Assembly Fireplace Operation Species Density Heat Value Maintenance and Safety DO’S DONT’S Repair Part Diagrams and Lists Model FireplaceBWBC500 / BWBC500I FACTORY-BUILT Fireplace and Components Your Duties This page Intentionally Left Blank 53D9032. Rev 1 03/03 53D9032. REV 1 03/03