CHIMNEY INSTALLATION
FIGURE 15
CENTERLINE
OF CHIMNEY
FIGURE 16
ACTUAL CENTER POINT
PLUMB LINE
PLUMB BOB
IMAGINARY CENTER POINT
TABLE 1
MINIMUM REQUIRED ROOF OPENING
MINIMUM FRAMED OPENING
ROOF PITCH | "S" SERIES DOUBLE | "E" SERIES DOUBLE |
WALL CHIMNEY | WALL CHIMNEY | |
|
|
|
0/12 | 14 1/2" x 14 1/2" | 17" x 17" |
1 12 | 14 1/2" x 14 5/8" | 17" x 17" 1/8" |
2/12 | 14 1/2" x 14 3/4" | 17" x 17" 1/4" |
3 12 | 14 1/2" x 15" | 17" x 17" 1/2" |
4/12 | 14 1/2" x 15 1/4" | 17" x 17" 3/4" |
5 12 | 14 1/2" x 15 3/4" | 17" x 18" 1/4" |
6/12 | 14 1/2" x 16 1/4" | 17" x 18" 3/4" |
7 12 | 14 1/2" x 16 7/8" | 17" x 19" 3/8" |
8/12 | 14 1/2" x 17 1/2" | 17" x 20" |
9 12 | 14 1/2" x 18 1/8" | 17" x 20" 5/8" |
10/12 | 14 1/2" x 18 7/8' | 17" x 21" 3/8" |
11 12 | 14 1/2" x 19 3/4" | 17" x 22" 1/4" |
12 12 | 14 1/2" x 20 1/2" | 17" x 23" |
|
|
|
INSTALLATION OF
| INLET AIR PIPE | FIGURE 17 |
CEILING JOIST | FLUE PIPE |
|
|
|
OUTER PIPE
FLUE
SUPPORT STRAPS
FASTEN SECURELY
FIRESTOP
CHIMNEY
SUPPORT
SNAP LOCK CHIMNEY
SUPPORT SECURLY
TO LOWER PIPES
BEFORE FASTENING
SUPPORT STRAPS
16
FIRESTOP SPACER
HEADER
CHIMNEY SECTION
INSTALLATION OF
INLET AIR PIPE
FLUE PIPE
FLOOR JOIST
FIRESTOP SPACER HEADER
CHIMNEY SECTION
53D9032. Rev 1 03/03