Monessen Hearth BWBC400I, BWB400I manual Chimney CAP Chase Installation

Page 61

CHIMNEY CAP CHASE INSTALLATION

The preinstalled chimney sections should be no more than 10 inches below the top of the chase. The installation should be planned so that either an 18-inch or 36-inch chimney section will be used for the top section. This is necessary to ensure complete engagement of the inlet air telescope and chimney cap into the top section.

CAUTION: Be careful around electrical wires to avoid the electrical shock hazard of contacting the wires with the metal chimney components.

NOTE: When two fireplace chimneys are terminated above the same chase, the centers of the chimney caps should be at least 24 inches apart to help prevent smoke from a fireplace in use from being drawn down the chimney of a fireplace that is not in use. Additional spacing between caps or staggering the height of the caps will further lessen the likelihood of this occurring.

1.Extend the chimney sections until the top of the chimney is not more than 10 inches below the top of the chase.

2.Center the hole in the chase cover over the chimney. The chase cover overhang should be lanced, formed over the chase and secured with nails. This prevents water from seeping under the chase cover. If two or more chase covers are to be used on the same chase, they should be soldered together to form two watertight seams.

3.Place the inlet air telescope inside the hole in the chase cover and lower it down into the mating pipe of the chimney until the flange on the telescope section rest on the flange of the chase cover. Note: All telescoping sections should extend a minimum of three inches inside the mating chimney pipes.

4.Install the SCL or SQL8 chimney cap by placing the cap into the matching duct telescope and flue telescope of the last chimney section as shown by Figure 23. Lower the cap until the brackets on the bottom of the chimney cap rests on the raised flange of the flat flashing, punch or drill 1/8 inch diameter holes in the raised flange of the flat flashing, and fasten the cap to the flashing with the No. 8 screws provided.

5.Check all parts of the chimney and chimney cap to assure that no parts have been damaged or bent during installation and that all parts have been installed properly.

NOTE: The metal used for the chimney and chimney cap has a rust-protective coating but the cut edges of the parts are not protected. To prevent rusting and rust staining of nearby structures, exposed parts of the chimney and chimney cap should be detergent-washed and painted with galvanized primer paint.

FIGURE 23

CHIMNEY CAP SUPPORT

BRACKETS. 3 PLACES.

SCREW

MAINTAIN CHIMNEY

SYSTEM AIR SPACE

CLEARANCES TO

COMBUSTIBLES

ABOVE ROOF LINE.

SCL OR SQ18 CHIMNEY CAP DESIGN INCORPORATES LONGER DUCT AND FLUE PIPE FOR CHASE TYPE INSTALLATION.

FLAT FLASHING OR CHASE COVER WITH 11-1/4" MIN. DIA. HOLE

10" MAX. SPACE BETWEEN CHIMNEY SECTION AND CHASE COVER.

3" MIN OVERLAP

INLET AIR TELESCOPE

CHASE

ROOF

21

53D9032. Rev 1 03/03

Image 61
Contents Series BWB400-SERIESTable of Contents Important Information Operation Guidelines Clearances Residential InstallationOutside AIR Connector Centerline Fireplace Location Installation Preparation Single Story Installation with Attic Space Floor Protection Fireplace MIN Floor Line with Raised Hearth Fireplace Components See for Illustration of Fireplace Components Described below Fireplace Installation Chimney Installation 17 x Chimney Offset Installation SF30 Firestop Spacer Chimney Offset and CAP InstallationChimney CAP Installation Intermediate Height Sections Inches Chimney Height and Offset ChartsChimney CAP Chase Installation Outside Combustion AIR Precautions and Recommendations Basement Installation Outside Combustion AIR Precautions & RecommendationsGAS Appliance Installation Combustion AIR AssemblyGAS Appliance Installation From Opening Trim InstallationPart a Glass Door Installation and FAN Accessory Fireplace Operation Species Density Heat Value Maintenance and Safety DO’S DONT’S Model Fireplace Parts Diagram and ListBWBC400/BWBC400I Except Blowers Limited WarrantyYour Duties This page intentionally left blank 53D9031. Rev 1 03/03 Appliance Installer BWB500, BWB500I, BWBC500 Congratulations Intended Product Usage Operation Guidelines Residential Installation Framing Corner Installation Side Wall Installation Joist Insulate Same Single Story Installation with Attic Space Brick or Stone Hearth Floor Line with Raised Hearth Fireplace Metal Safety Strip SCS Model Description Fireplace Installation Chimney Installation 17 x Although Both Halves 14-1/2 Chimney CAP Installation Straight RUN Chimney Sections Intermediate Height Inches Chimney CAP Chase Installation Outside Combustion AIR Precautions & Recommendations Outside Combustion AIR Recommendations Model AK4 Combustion AIR Assembly GAS Appliance Installation Applying Decorative Trim to the Fireplace Outline Fireplace Firebrick FAN Assembly Fireplace Operation Species Density Heat Value Maintenance and Safety DO’S DONT’S Model Fireplace Repair Part Diagrams and ListsBWBC500 / BWBC500I FACTORY-BUILT Fireplace and Components Your Duties This page Intentionally Left Blank 53D9032. Rev 1 03/03 53D9032. REV 1 03/03