FLOOR PROTECTION
If this fireplace is installed on a combustible floor, the floor area 20 inches in front of, and 12 inches either side of the fireplace opening must be protected by an insulating noncombustible hearth extension. This hearth extension may be either minimum
The insulation used in the H2066 hearth extension has a thermal conductivity (K Factor) of .43. If you do construct a hearth extension equivalent to the H2066, be sure the insulation you use has enough compressive strength to support the weight of the covering materials and persons standing on it, and insulating qualities equal too or better than the ˚" covering provided by the H2066.
FIGURE 10
12"
MIN.
6" MIN. | 20" |
| MIN. |
12"
MIN.
6" MIN. OF BRICK
OR STONE FROM TOP
OF PLATFORM.
BRICK OR STONE HEARTH EXTENSION 66" LONG MIN.
FIREPLACE
HEARTH
FIREPLACE
HEARTH
PLATFORM
DO NOT PLACE HEARTH
MATERIALS ABOVE
OPENING OF FIREPLACE.
METAL SAFETY STRIP
PLATFORM MAY EXTEND UNDER
HEARTH EXTENSION IF DESIRED
ALTERNATE BRICK OR STONE HEARTH EXTENSION
FOR USE WITH SF42A/SF42AI FIREPLACES.
BRICK OR STONE HEARTH EXTENSION 66" LONG MIN.
DO NOT PLACE HEARTH MATERIALS ABOVE OPENING OF FIREPLACE.
SAFETY STRIP REQUIRED WHEN UNIT IS PLACED
ON COMBUSTIBLE FLOOR OR PLATFORM
12"
MIN.
6" MIN. | 20" |
| MIN. |
ALTERNATE BRICK OR STONE HEARTH EXTENSION
FOR USE WITH SCF42A/SCF42AI FIREPLACES.
BRICK OR STONE HEARTH
EXTENSION 66" LONG MIN.
10
FIREPLACE
HEARTH
DO NOT BLOCK LOUVERED OPENINGS
PLATFORM
METAL SAFETY STRIP
53D9032. Rev 1 03/03