Monessen Hearth BWBC400I, BWB400I manual FAN Assembly

Page 68

GLASS DOOR INSTALLATION AND FAN ACCESSORY

GLASS DOOR INSTALLATION

This fireplace has been tested and listed for use with optional Model GD42P or GD42PB glass doors. For installation of the Models GD42P or GD42PB glass doors, see the instructions provided with the doors.

FAN ASSEMBLY

The model BWBC500 and BWBC500I Fireplaces may be equipped with a accessory fan Model FA2. If the fireplace is to be equipped with this accessory at anytime, the JB1 junction box assembly must be installed on the fireplace as shown by Figures 32 and 33 during the installation of the fireplace. Unless the JB1 junction box is installed at this time, wall finishing materials must be removed to gain access to the side of the fireplace to install the JB1 junction box at a later date. Complete Installation and Operation Instructions for the FA2 Fan are included in the package with this accessory.

Note: A rectangular switch knockout is provided on the lower right hand face of the fireplace.

MODEL JBI JUNCTION BOX INSTALLATION

FIGURE 32

FASTEN MODEL JBI JUNCTION

BOX TO THE SIDE OF THE

FIREPLACE WITH THE TWO

SHEET METAL SCREWS REMOVED

FROM JUNCTION BOX

OPENING COVER.

NOTE: THE THREE PRONG RECEPTACLE

AND ITS COVER MUST BE EXPOSED AND

THE COVER PLATE MUST BE REMOVABLE

FOR INSPECTION OF WIRING CONNECTION

ONCE THE FIREPLACE IS INSTALLED.

REMOVE JUNCTION BOX COVER FROM FIREPLACE.

GAS APPLIANCE

OPENING COVER

JUNCTION BOX

OPENING COVER

BELK LOUVER KIT

FIGURE 33

M1

M2

(FAN ASSEMBLIES)

CORDSET

120V, 60HZ

 

SWITCH

 

(SPST)

JUNCTION BOX

OF FIREPLACE

 

 

BLACK

TO FUSE OR

 

 

 

 

WHITE

 

 

CIRCIUT BREAKER

 

 

 

 

 

 

 

 

 

 

 

GROUND

 

 

 

NOTE: THE JB1 JUNCTION BOX SHOULD BE INSTALLED AND THE RECEPTACLE WIRED TO THE ELECTRICAL SYSTEM OF THE STRUCTURE AT THE TIME OF INSTALLATION OF THE FIREPLACE OF THE FA2 FAN ASSEMBLY IS TO BE USED.

28

53D9032. Rev 1 03/03

Image 68
Contents BWB400-SERIES SeriesTable of Contents Important Information Operation Guidelines Residential Installation ClearancesOutside AIR Connector Centerline Fireplace Location Installation Preparation Single Story Installation with Attic Space Floor Protection Fireplace MIN Floor Line with Raised Hearth Fireplace Components See for Illustration of Fireplace Components Described below Fireplace Installation Chimney Installation 17 x Chimney Offset Installation Chimney Offset and CAP Installation SF30 Firestop SpacerChimney CAP Installation Chimney Height and Offset Charts Intermediate Height Sections InchesChimney CAP Chase Installation Outside Combustion AIR Precautions and Recommendations Outside Combustion AIR Precautions & Recommendations Basement InstallationCombustion AIR Assembly GAS Appliance InstallationGAS Appliance Installation Trim Installation From OpeningPart a Glass Door Installation and FAN Accessory Fireplace Operation Species Density Heat Value Maintenance and Safety DO’S DONT’S Parts Diagram and List Model FireplaceBWBC400/BWBC400I Limited Warranty Except BlowersYour Duties This page intentionally left blank 53D9031. Rev 1 03/03 Appliance Installer BWB500, BWB500I, BWBC500 Congratulations Intended Product Usage Operation Guidelines Residential Installation Framing Corner Installation Side Wall Installation Joist Insulate Same Single Story Installation with Attic Space Brick or Stone Hearth Floor Line with Raised Hearth Fireplace Metal Safety Strip SCS Model Description Fireplace Installation Chimney Installation 17 x Although Both Halves 14-1/2 Chimney CAP Installation Straight RUN Chimney Sections Intermediate Height Inches Chimney CAP Chase Installation Outside Combustion AIR Precautions & Recommendations Outside Combustion AIR Recommendations Model AK4 Combustion AIR Assembly GAS Appliance Installation Applying Decorative Trim to the Fireplace Outline Fireplace Firebrick FAN Assembly Fireplace Operation Species Density Heat Value Maintenance and Safety DO’S DONT’S Repair Part Diagrams and Lists Model FireplaceBWBC500 / BWBC500I FACTORY-BUILT Fireplace and Components Your Duties This page Intentionally Left Blank 53D9032. Rev 1 03/03 53D9032. REV 1 03/03