INSTALLATION PREPARATION
FIGURE 7
SINGLE STORY INSTALLATION WITH
ATTIC SPACE
SC CHIMNEY CAP
| FLUE OUTLET HEIGHT |
STORM COLLAR | 3 FT. MIN. OR 2 FT. ABOVE |
| ANY POINT WITHIN 10 FT. |
FLASHING |
|
(612 OR 1212) |
|
| ATTIC SPACE |
| SEE TABLE 1 FOR |
| ROOF OPENING |
| SIZE |
14 FT MIN. | SF FIRESTOP SPACER |
| (1 3/4" AIR SPACE CLEARANCE |
| TO COMBUSTIBLES) |
| 14 1/2" SQUARE |
| OPENING IN JOIST |
| 2" MIN. CLEARANCE |
| TO COMBUSTIBLES |
FIGURE 9
MULTIPLE STORY INSTALLATION
FIGURE 8
PREFERRED
LOCATION
POOR
LOCATION
MODEL SC
CHIMNEY CAP
STORM COLLAR (INCLUDED WITH CAP)
FLASHING (612 OR 1212)
14 1/2" SQUARE HOLE IN JOIST (1 3/4" AIR SPACE CLEARANCE
TO COMBUSTIBLES)
MAX. INSTALLATION
HEIGHT - 86 FT. CHIMNEY
14 1/2" SQUARE HOLE IN JOIST (1 3/4" AIR SPACE CLEARANCE
TO COMBUSTIBLES)
FLUE OUTLET HEIGHT
3 FT. MIN.
ATTIC SPACE
SEE TABLE 1 FOR
ROOF OPENING SIZE
FIRESTOP SPACER SF
THIRD FLOOR AREA
2" CLEARENCE TO
COMBUSTIBLES (MIN.)
FIRESTOP SPACER SF
SECOND FLOOR AREA
FIRESTOP SPACER SF
FIRST FLOOR AREA
9
53D9032. Rev 1 03/03