11. OPERATING INSTRUCTIONS
FOR YOUR SAFETY READ BEFORE OPERATING
WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION
MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
A) This appliance is equipped with a pilot which must be lit |
| • If you cannot reach your gas supplier, call the fire | |||
| by hand by following these instructions exactly. |
|
| department. |
|
B) | BEFORE LIGHTING smell all around the appliance area for | C) | Use only your hand to push in or turn the gas control | ||
| gas, and next to the floor because some gas is heavier |
| knob. Never use tools. If the knob will not push in or | ||
| than air and will settle on the floor. |
|
| turn by hand, do not try to repair it . Call a qualified | |
WHAT TO DO IF YOU SMELL GAS: |
|
| service technician. Force or attempted repair may result | ||
| • Do not try to light any appliance. |
|
| in a fire or explosion. |
|
| • Do not touch any electrical switch; do not use any | D) | Do not use this appliance if any part has been under | ||
| phone in your building. |
|
| water. Immediately call a qualified service technician to | |
| • Immediately call your gas supplier from a neighbor’s |
| inspect the appliance and to replace any part of the | ||
| phone. follow the gas suppliers instructions. |
| control system and any gas control which has been | ||
|
|
|
| under water |
|
| LIGHTING INSTRUCTIONS |
|
| • |
|
1. | STOP! Read the safety information above. |
|
|
| |
2. | Turn off all electrical power to the appliance. |
| 8. | EUROSIT VALVE: |
|
3. | Turn the gas control knob clockwise | to the |
| Turn gas control knob | to |
| “off’ position. |
|
| the “LO” position. Then turn knob to the desired | |
4. | Open door. Wait five (5) minutes to clear out any gas. |
| setting. |
| |
| Close door. If you smell gas including near the floor, |
|
|
| |
| STOP! Follow “B” in the above safety information. |
|
|
|
If you don’t smell gas go to next step.
5.Find the pilot located to the right between the front and rear burner.
6. Turn gas control knob | to |
“PILOT”. |
|
7.Push the gas control knob in fully and hold. Immediately light the pilot by pushing the piezo spark ignitor. Keep knob Depressed for about 30 seconds after pilot is lit.
Release knob. If pilot goes out, repeat steps 4 through 6. WARNING The gas valve has an lockout device which will
not allow the pilot burner to be
• | If the knob does not pop up when released, stop and | 9. NOVASIT VALVE: |
| |
| Immediately call your service technician or gas | Turn gas control knob | to | |
| supplier. | |||
• | the “ON” position. Flip burner switch to “ON” then | |||
If the pilot will not stay lit after several tries, turn the | ||||
|
|
gas control knob to “OFF” and call your service technician or gas supplier.
turn “HI / LO” knob to the desired setting.
10.Turn on all electrical power to the unit
NOTE: Check to be sure the pilot flame engulfs the thermocouple and that the burners light completely.
TO TURN OFF GAS TO APPLIANCE
1.Turn the gas control knob clockwise to “OFF” DO NOT FORCE
2.Turn off all electrical power to the appliance if service is to be performed.
3.NOVASIT VALVE: Flip burner switch to off.
14