Enviro 828 BV. FS, 828 BV. INS Operating Instructions, For Your Safety Read Before Operating

Page 14

11. OPERATING INSTRUCTIONS

FOR YOUR SAFETY READ BEFORE OPERATING

WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION

MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.

A) This appliance is equipped with a pilot which must be lit

 

• If you cannot reach your gas supplier, call the fire

 

by hand by following these instructions exactly.

 

 

department.

 

B)

BEFORE LIGHTING smell all around the appliance area for

C)

Use only your hand to push in or turn the gas control

 

gas, and next to the floor because some gas is heavier

 

knob. Never use tools. If the knob will not push in or

 

than air and will settle on the floor.

 

 

turn by hand, do not try to repair it . Call a qualified

WHAT TO DO IF YOU SMELL GAS:

 

 

service technician. Force or attempted repair may result

 

• Do not try to light any appliance.

 

 

in a fire or explosion.

 

 

• Do not touch any electrical switch; do not use any

D)

Do not use this appliance if any part has been under

 

phone in your building.

 

 

water. Immediately call a qualified service technician to

 

• Immediately call your gas supplier from a neighbor’s

 

inspect the appliance and to replace any part of the

 

phone. follow the gas suppliers instructions.

 

control system and any gas control which has been

 

 

 

 

under water

 

 

LIGHTING INSTRUCTIONS

 

 

 

1.

STOP! Read the safety information above.

 

 

 

2.

Turn off all electrical power to the appliance.

 

8.

EUROSIT VALVE:

 

3.

Turn the gas control knob clockwise

to the

 

Turn gas control knob counter-clockwise

to

 

“off’ position.

 

 

the “LO” position. Then turn knob to the desired

4.

Open door. Wait five (5) minutes to clear out any gas.

 

setting.

 

 

Close door. If you smell gas including near the floor,

 

 

 

 

STOP! Follow “B” in the above safety information.

 

 

 

If you don’t smell gas go to next step.

5.Find the pilot located to the right between the front and rear burner.

6. Turn gas control knob counter-clockwise

to

“PILOT”.

 

7.Push the gas control knob in fully and hold. Immediately light the pilot by pushing the piezo spark ignitor. Keep knob Depressed for about 30 seconds after pilot is lit.

Release knob. If pilot goes out, repeat steps 4 through 6. WARNING The gas valve has an lockout device which will

not allow the pilot burner to be re-lit until the thermocouple has cooled.

If the knob does not pop up when released, stop and

9. NOVASIT VALVE:

 

 

Immediately call your service technician or gas

Turn gas control knob counter-clockwise

to

 

supplier.

the “ON” position. Flip burner switch to “ON” then

If the pilot will not stay lit after several tries, turn the

 

 

gas control knob to “OFF” and call your service technician or gas supplier.

turn “HI / LO” knob to the desired setting.

10.Turn on all electrical power to the unit

NOTE: Check to be sure the pilot flame engulfs the thermocouple and that the burners light completely.

TO TURN OFF GAS TO APPLIANCE

1.Turn the gas control knob clockwise to “OFF” DO NOT FORCE

2.Turn off all electrical power to the appliance if service is to be performed.

3.NOVASIT VALVE: Flip burner switch to off.

14

Image 14
Contents For Your Safety What to do if YOU Smell GASSafety Precautions GeneralCode Approvals Table of ContentsSpecifications Fireplace Insert Clearances to Combustibles For Installations Above 2000 FeetDimensions and Clearances to Combustibles Freestanding Clearances to CombustiblesDeciding Where to Locate Your Freestanding Stove Primary InstallationAssembly and Installation Instructions Preparation for InstallationAssembling Your Envirogas 828 Freestanding Appliance Electrical Requirements Optional FANOrifice SIZES, Pressures and Btus GAS Line Connection and TestingNever USE Open Flame for Leak Testing Automatic Flue GAS Spill Switch Venting Venting Freestanding Models AIR Shutter Adjustment Installing the Glowing Embers Installing the LOGFor Your Safety Read Before Operating Operating InstructionsRoutine Maintenance Trouble Shooting Problem Possible Cause SolutionParts and Accessories Service Parts available from your local Envirogas DealerWarranty To the DealerInstallation Data Sheet EG-828 Insert BV. FPI