Enviro 828 BV. INS GAS Line Connection and Testing, Never USE Open Flame for Leak Testing

Page 9

7. GAS LINE CONNECTION AND TESTING

WARNING: Only persons licensed to work with gas piping can make the gas connections to this appliance.

This appliance is equipped with a 3/8” stainless steel flex line from the valve. This line may be routed through the hole in the rear

of the pedestal, or on inserts, routed through the fire box sides. An adapter plate is available for installations that do not allow flex pipe through cabinetry.

NOTE: Consult your local authorities and in CAN. the CAN/CGA-B149 (1 or 2) Installation Code, For USA gas installations follow either local codes or the current edition of the National Fuel Gas Code ANSI. Z223.1.

The appliance and its shutoff valves must be disconnected from the gas supply piping system during any pressure testing where the pressure exceeds 1/2 PSIG (3.45 kPa) or damage will occur to the valve.

The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa).

Always check for gas leaks with a soap and water solution or an approved manner after completing required pressure tests.

ORIFICE SIZES, PRESSURES AND BTU'S

The efficiency rating of this appliance is a product thermal efficiency rating determined under continuous operating conditions and was

determined independently of any installed system. All models are equipped with a variable output gas control.

 

NATURAL GAS

PROPANE

ORIFICES (Front / Rear)

#51 DMS / #49 DMS

#59 DMS / #56 DMS

Manifold Press:

3.5" wc

/

0.87 kPa

10.0" wc

/

2.49 kPa

Min. Manifold Press:

2.1” wc

/

0.52 kPa

6.2" wc

/

1.54 kPa

Max. Supply Press:

7.0" wc

/

1.74 kPa

13.0" wc

/

3.23 kPa

Desired Supply Press:

7.0" wc

/

1.74 kPa

11.0” wc

/

2.74 kPa

Min. Supply Press:

5.0" wc

/

1.25 kPa

10.5" wc

/

2.62 kPa

Max. BTU/H Input:

26,500

/

7.6 kW

26,500

/

7.6 kW

Min. BTU/H Input:

21,000

/

6.15 kW

21,000

/ 6.15 kW

MOBILE HOME Manifold Press:

4.0" wc

/

1.00 kPa

10.0" wc

/

2.49 kPa

In Canada and the United States these appliances are certified for altitudes of 0-4500 ft. / 1370 m.

TO TEST VALVE PRESSURES

-Turn set screw counter clockwise to loosen, 2 turns. -Place 5/16" I.D. hose over pressure tap system.

-When finished, release pressure, remove hose & tighten set screw.

EUROSIT VALVE:

NOVASIT VALVE: The pressure taps are located on the front of the valve through the control panel.

(Left - manifold pressure, Right - inlet pressure).

The pressure taps are located through the left side of the pedestal on the left side of the valve

(Rear - inlet pressure, Front - manifold pressure).

NEVER USE OPEN FLAME FOR LEAK TESTING

9

Image 9
Contents What to do if YOU Smell GAS For Your SafetyGeneral Safety PrecautionsTable of Contents SpecificationsCode Approvals Dimensions and Clearances to Combustibles For Installations Above 2000 FeetFireplace Insert Clearances to Combustibles Freestanding Clearances to CombustiblesPrimary Installation Deciding Where to Locate Your Freestanding StovePreparation for Installation Assembly and Installation InstructionsAssembling Your Envirogas 828 Freestanding Appliance Optional FAN Electrical RequirementsGAS Line Connection and Testing Never USE Open Flame for Leak TestingOrifice SIZES, Pressures and Btus Venting Automatic Flue GAS Spill SwitchVenting Freestanding Models AIR Shutter Adjustment Installing the LOG Installing the Glowing EmbersOperating Instructions For Your Safety Read Before OperatingRoutine Maintenance Problem Possible Cause Solution Trouble ShootingService Parts available from your local Envirogas Dealer Parts and AccessoriesTo the Dealer WarrantyEG-828 Insert BV. FPI Installation Data Sheet