12. ROUTINE MAINTENANCE

Periodically check to ensure that the "B-Vent" venting system is clear and that a negative draft is present when the unit is operating. On fireplace insert models there is a draft inspection tube the opening is located on the right hand side behind the hinged side. A vacuum should be present at the opening.

Periodically check the pilot and burner flames (See Fig.11)

CLEANING OF GLASS

Do not clean glass when hot

It will be necessary to clean the ceramic glass periodically. During a cold start up condensation will sometimes form on the glass, this is a normal condition with all gas fireplaces and stoves. However, sometimes this condensation can allow dust and lint to cling to the glass surface. Also, sometimes initial paint curing of the appliance can leave behind a slight film on the glass. This is a temporary problem. It is therefore recommended that the glass be cleaned initially after about the first two weeks of use.

After that, depending upon the amount of use, cleaning should be required no more than two or three times per season.

To clean the door, use a mild glass cleaner and a soft cloth. Abrasive cleaners will damage the glass surface.

OPENING THE GLASS DOOR

Turn unit off and wait until the appliance has cooled down.

1.Open the right hand hinged side flap which will expose a door fastener. Using a 1/2" wrench, loosen the fastener.

2.Due to the shape of the bay window door. You must also open the left hand side flap before attempting to open the door.

3.Ensure the door is properly fastened after cleaning before attempting to re-light the appliance.

TO REPLACE DOOR AND GLASS ASSEMBLY

The glass in this appliance is an integral part of the door assembly. If the glass is damaged or broken a

15

replacement door assembly including glass must be fitted.

To Replace

open door fully

Lift door vertically so that hinge pins lift out of hinge receivers.

Return assembly to dealer.

The Door and glass assembly must be replaced as a complete unit by your ENVIROGAS Dealer. No

substitute materials are allowed.

FOR CLEANING THE INSIDE OF THE FIREBOX

Remove the log carefully from the firebox. Gently remove the embers and place on a piece of paper towel.

Vacuum the firebox thoroughly. Carefully clean off any dust on the logs and remove any lint from the main burners and pilot burner.

After carefully replacing the log and embers in their correct positions, and the door has been resealed, re-light the pilot, following the instructions on the attached label.

CLEARANCES MUST BE SUFFICIENT TO ALLOW ACCESS FOR MAINTENANCE AND SERVICE

LUBRICATING THE BLOWER

Every 6 months the blower should be lubricated if installed

1.Turn the unit off and remove the log set.

2.Remove the burner tray assembly by removing the screw on either side of the tray, between the front and rear burners. Lift tray out.

3.Remove the 8 screws that hold the blower mounting plate to the back firewall.

4.Carefully pull the blower assembly into the firebox, exposing the blower lubricating holes ( located on the top of the motor housing on either side of the label). Add 2 drops of SAE 20 oil.

5.If removal of the blower is necessary, disconnect the blower leads from the harness. Remove the blower.

6.To re-install, check mounting plate gasket and reverse steps 1 through 4.

Image 15
Contents What to do if YOU Smell GAS For Your SafetyGeneral Safety PrecautionsTable of Contents SpecificationsCode Approvals Freestanding Clearances to Combustibles For Installations Above 2000 FeetDimensions and Clearances to Combustibles Fireplace Insert Clearances to CombustiblesPrimary Installation Deciding Where to Locate Your Freestanding StovePreparation for Installation Assembly and Installation InstructionsAssembling Your Envirogas 828 Freestanding Appliance Optional FAN Electrical RequirementsGAS Line Connection and Testing Never USE Open Flame for Leak TestingOrifice SIZES, Pressures and Btus Venting Automatic Flue GAS Spill SwitchVenting Freestanding Models AIR Shutter Adjustment Installing the LOG Installing the Glowing EmbersOperating Instructions For Your Safety Read Before OperatingRoutine Maintenance Problem Possible Cause Solution Trouble ShootingService Parts available from your local Envirogas Dealer Parts and AccessoriesTo the Dealer WarrantyEG-828 Insert BV. FPI Installation Data Sheet