Enviro 828 BV. FS Assembly and Installation Instructions, Preparation for Installation

Page 6

* As specified in CGA B149 Installation Codes (1991) Note: Local Codes or Regulations may require different clearances.

5. ASSEMBLY AND INSTALLATION INSTRUCTIONS

PREPARATION FOR INSTALLATION

Remove the packaging from the appliance, pedestal or surround panels, check to make sure there is no damage. Carefully check the glass door. Do not use the unit if it is damaged. In the event damage is found please report it to both the courier and your dealer as soon as possible.

ASSEMBLING AND INSTALLING YOUR ENVIROGAS 828 FIREPLACE INSERT

1.Carefully clean the fireplace and flue before installing the stove. Failure to do so may result in fumes or dirt being blown into the room and may cause a fire leading to death or serious injury.

2.Remove the two wood screws that attach the stove to its pallet. These are located through the square openings immediately behind the surround panel mounting bracket

on each side of the unit. ( #2 Robertson screwdriver ) (See A in Figure 1)

3.Open hinged side flap, open door, remove log and ember set and all wrapping material from the stove . Remove wrapping material from log and embers and check for any damage. If damage is observed do not use unit and contact your local dealer.

4.Remove the vent collar plate from the top of the stove by unscrewing the T20 Torx screw, located on the center top of the stove and slide backwards. (SEE FIGURE 4)

Properly secure the vent collar plate to the approved flexible pipe liner previously installed in the chimney. Be careful not to over stretch the liner.

5.Place the unit part way into the fireplace. Connect the fireplace insert's flexible gas line to the household gas supply using locally approved methods.

6.For units with optional fan place the electric cable so it can be connected to the power supply.

7.Push the unit into its final position in the fireplace insuring that it is stable and level.

8.Reinstall the vent collar plate to the stove by sliding it along the draft hood and secure with the screw.

9.Remove the hinged side flaps from the panel mounting brackets on each side of the unit (fig 5).

10.Remove the top grill bar. Undo the 1/4" nuts holding the stove top ( 7/16" wrench). Lift top up and remove.

11.For units with optional fan connect surround panel

wire harness to the stove wire harness following the wiring diagram in fig 8.

12.Place the assembled surround panel around the stove, in front of the surround mounting brackets. Make sure the top surround panel sits flat on the stove.

Figure 5

6

Image 6
Contents For Your Safety What to do if YOU Smell GASSafety Precautions GeneralTable of Contents SpecificationsCode Approvals Fireplace Insert Clearances to Combustibles For Installations Above 2000 FeetDimensions and Clearances to Combustibles Freestanding Clearances to CombustiblesDeciding Where to Locate Your Freestanding Stove Primary InstallationAssembly and Installation Instructions Preparation for InstallationAssembling Your Envirogas 828 Freestanding Appliance Electrical Requirements Optional FANGAS Line Connection and Testing Never USE Open Flame for Leak TestingOrifice SIZES, Pressures and Btus Automatic Flue GAS Spill Switch VentingVenting Freestanding Models AIR Shutter Adjustment Installing the Glowing Embers Installing the LOGFor Your Safety Read Before Operating Operating InstructionsRoutine Maintenance Trouble Shooting Problem Possible Cause SolutionParts and Accessories Service Parts available from your local Envirogas DealerWarranty To the DealerInstallation Data Sheet EG-828 Insert BV. FPI