Enviro 828 BV. FS, 828 BV. INS owner manual Venting, Automatic Flue GAS Spill Switch

Page 10

8. VENTING

WARNING: THIS APPLIANCE HAS BEEN DESIGNED TO OPERATE BY DRAWING COMBUSTION AIR AND

DILUTION AIR FROM THE ROOM. IT IS ALSO DESIGNED TO DRAW ROOM AIR FOR PROPER HEAT

CIRCULATION FROM THE SIDES OF THE UNIT. BLOCKING OR MODIFYING THE LOUVERS IN ANY WAY CAN

CREATE HAZARDOUS SITUATIONS, EITHER THROUGH POOR VENTING OR BY OVERHEATING. IT IS IMPORTANT THAT THIS UNIT HAS SUFFICIENT AIR CIRCULATION FOR PROPER VENTING AND COMBUSTION. PROVISIONS MUST BE MADE FOR THE SUPPLY OF ADEQUATE COMBUSTION AND VENTILATION AIR. THESE OPENINGS MUST NOT BE BLOCKED.

THE APPLIANCE MUST NOT BE CONNECTED TO A CHIMNEY FLUE SERVICING

A SEPARATE SOLID FUEL BURNING APPLIANCE.

AUTOMATIC FLUE GAS SPILL SWITCH

NOTE: THIS HEATER MUST BE PROPERLY CONNECTED TO A VENTING SYSTEM. THIS HEATER IS EQUIPPED

WITH A VENT SAFETY SHUTOFF SYSTEM DESIGNED TO PROTECT AGAINST IMPROPER VENTING OF

COMBUSTION PRODUCTS.

THIS SAFETY SWITCH IS LOCATED ON THE REAR OF THE APPLIANCE CLOSE TO

THE DRAFT HOOD RELIEF OPENING.

IF THE SWITCH TRIPS MORE THAN ONCE THE VENTING SHOULD BE INSPECTED BY A QUALIFIED SERVICE TECHNICIAN FOR POSSIBLE BLOCKAGE OR SEVERE DOWN DRAFT CONDITIONS

This stove can be vented with aluminum or stainless steel flex vent and/or certified 4" Type B Gas Vent. The flue collar of the appliance will fit inside of a standard 4” vent and may be fastened directly to the vent. Check periodically that the vent is unrestricted and an adequate draft is present when the unit is in operation.

WARNING: Operation of this heater when not connected to a properly installed and maintained venting system or tampering with the vent safety shutoff system can result in carbon monoxide (CO) poisoning and possible death.

A. VENTING FIREPLACE INSERTS

The ENVIROGAS 828 insert may be installed and vented into any solid fuel fireplace that has been installed in accordance with the National, Provincial/State and local building codes and has been constructed of non-combustible materials.

An approved 4" chimney liner, throat connector, and rain cap must be installed, to ensure a tight seal, top performance, safety

and efficiency. Carefully follow the manufacturers instructions which accompany the chimney liner kit.

Measure the height of the chimney beforehand and purchase the appropriate kit. Never attempt to over stretch a flexible liner to accommodate the height of the chimney.

Install sealed throat connector to prevent leakage of room air through chimney.

Any flue damper must be removed or blocked permanently in the open position.

The chimney must be clean, in good working order and

10

Image 10
Contents For Your Safety What to do if YOU Smell GASSafety Precautions GeneralSpecifications Table of ContentsCode Approvals Fireplace Insert Clearances to Combustibles For Installations Above 2000 FeetDimensions and Clearances to Combustibles Freestanding Clearances to CombustiblesDeciding Where to Locate Your Freestanding Stove Primary InstallationAssembly and Installation Instructions Preparation for InstallationAssembling Your Envirogas 828 Freestanding Appliance Electrical Requirements Optional FANNever USE Open Flame for Leak Testing GAS Line Connection and TestingOrifice SIZES, Pressures and Btus Automatic Flue GAS Spill Switch VentingVenting Freestanding Models AIR Shutter Adjustment Installing the Glowing Embers Installing the LOGFor Your Safety Read Before Operating Operating InstructionsRoutine Maintenance Trouble Shooting Problem Possible Cause SolutionParts and Accessories Service Parts available from your local Envirogas DealerWarranty To the DealerInstallation Data Sheet EG-828 Insert BV. FPI