Enviro 828 BV. FS For Installations Above 2000 Feet, Dimensions and Clearances to Combustibles

Page 4

FOR INSTALLATIONS ABOVE 2000 FEET

In Canada, these appliances are certified for altitudes of 0-2,000 feet and must be derated by 10% for installation at elevations between 2,000 and 4,500 feet.

In the USA, these appliance are certified for elevations up to 2,000 feet. For elevations above 2,000 feet, input should be reduced 4% for each 1,000 feet above sea level.

The efficiency rating of this appliance is a product thermal efficiency rating determined under continuous

operating conditions and was determined independently of any installed system.

3. DIMENSIONS AND CLEARANCES TO COMBUSTIBLES

FIREPLACE INSERT CLEARANCES TO COMBUSTIBLES:

A. Mantle pillar to stove

10" /

 

25 cm

 

 

B. Stove top to 8" wide mantle

12" / 31

 

cm

 

 

Stove must sit on a non-combustible

 

surface, the width and depth of the

 

insert

 

 

Maintain sufficient clearances

 

 

for operation, service and maintenance

 

OTHER DIMENSIONS

 

 

A. Depth of unit into fireplace

11¼" /

 

28.5 cm

 

 

B. Depth of unit out of fireplace

8 ¾” / 22.2 cm

 

C. Minimum firebox size W 26" x H 20” x D 20"

Figure 1

(W 66 x H 50 x D 50 cm)

FREESTANDING CLEARANCES TO COMBUSTIBLES:

A. Side wall to stove

10"

B. Rear wall to stove

4"

C. Combustible to stove Top

22"

D. Floor to stove

0"

E. Corner clearance

2"

F. Alcove depth

48"

Maintain sufficient clearances

 

for service and maintenance

 

Figure 2

4

Image 4
Contents For Your Safety What to do if YOU Smell GASSafety Precautions GeneralSpecifications Table of ContentsCode Approvals For Installations Above 2000 Feet Dimensions and Clearances to CombustiblesFireplace Insert Clearances to Combustibles Freestanding Clearances to CombustiblesDeciding Where to Locate Your Freestanding Stove Primary InstallationAssembly and Installation Instructions Preparation for InstallationAssembling Your Envirogas 828 Freestanding Appliance Electrical Requirements Optional FANNever USE Open Flame for Leak Testing GAS Line Connection and TestingOrifice SIZES, Pressures and Btus Automatic Flue GAS Spill Switch VentingVenting Freestanding Models AIR Shutter Adjustment Installing the Glowing Embers Installing the LOGFor Your Safety Read Before Operating Operating InstructionsRoutine Maintenance Trouble Shooting Problem Possible Cause SolutionParts and Accessories Service Parts available from your local Envirogas DealerWarranty To the DealerInstallation Data Sheet EG-828 Insert BV. FPI