Vermont Casting 36CDVRRN, 36CDVTRN installation instructions Venting Components

Page 27

CDV Series Direct Vent Gas Fireplace

Venting Components

 

 

20010581 - Straight Out the Back Termination

 

 

10001953 - Through-the-Wall Termination

 

 

(for other than straight out the back on rear vent)

 

 

Starter Kit -

 

 

Model 7TCRVT: Straight thru Rear Vent for 7” - 13” Vent

 

 

Application

 

 

Model 7TCD45KT: Vent Kit for 45° Installation or 13” - 32”

 

 

Rear Vent application

 

 

Starter Kit* - Model 7TDVSKV - Vertical Venting

 

 

for 7TDVSKV-A order 1/12 to 6/12 roof pitch

 

 

for 7TDVSKV-B order 7/12 to 12/12 roof pitch

*NOTE: Must order a 7TCDV90 elbow

for 7TDVSKV-F order flat roof

Starter Kit for Below Grade Installation

for rear vent to vertical application only.

Model 7TDVSKS -Snorkel Kit (Twist Lock Pipe)

 

 

 

 

Model 7FDVSKS -Snorkel Kit (Flex Vent Pipe)

 

 

 

 

 

90o Elbow

 

 

 

 

7TCDV90 - For Rear to Vertical

 

 

 

 

7TDV90 - For Extended Run

Telescopic vent sections

7TDVP1117 -11” to 17” adjustable length 7TDVP3567 -35” to 67” adjustable length

Pipe sections for vertical or horizontal venting

Model 7TDVP8”

-

4 per box

 

Model 7TDVP12”

-

4 per box

 

Model 7TDVP24”

-

4 per box

 

Model 7TDVP36”

 

 

 

Model 7TDVP48”

 

 

 

 

 

 

 

Firestop Spacer

 

 

 

Model 7DVFS

 

 

 

 

 

 

 

Attic Insulation Shield

 

 

 

Model 7DVAIS

 

 

 

Vertical/Horizontal Combination Offset Support

Model 7DVCS

20010175

27

Image 27
Contents Builder Direct Vent Models Table of Contents Installation & Operating Instructions Locating Your FireplacePlease Review the Following Carefully Must be adhered to Fireplace Dimensions Rear VentFraming Dimensions 36CDVR36CDVT Fireplace Dimensions Top VentClearance to Combustibles MantelsHearth Gas Specifications Hood InstallationFraming and Finishing Final FinishingHigh Elevations Gas Line InstallationRemote ON/OFF Switch Gas Inlet and Manifold PressuresLocation of Vent Termination General VentingGeneral Venting Information Termination Location Canadian Installations1 US Installations2Flex Vent Pipes Canadian InstallationsUSA Installations General Information Assembling Vent PipesFrom Rear of Unit How to Use the Vent Graph36CDVR Venting Rear Wall Venting ApplicationsStep Rear Wall Installation Twist Lock PipeBend flex pipe up 90 as close to fireplace as pos- sible Rear Wall Vent Installations Flex Vent PipeSecure collar in place, slide termination into collar Vertical Sidewall ApplicationsMaximum horizontal vent run Vertical Sidewall InstallationAlways install hori- zontal venting on a level plane Vertical Through-the-Roof Applications Below Grade InstallationsEnlarged ends of the vent section always face downward. Fig Vertical Through-the-Roof Installation36CDVT Vertical Venting Typical straight-up installation+ B = 17 5.2m Max Always install horizontal venting on a level plane Vertical Sidewall InstallationsThrough the wall Example Maximum horizontal length Roof and ceiling supports Min 610 mm Venting Components Glass Information Glass CleaningWindow Frame Assembly Removal Operating InstructionsRN/RP & EN/EP Models Flame CharacteristicsFlame & Temperature Adjustment LogsLighting and Operating Instructions To Turn Off Gas to FireplaceWhat to do if YOU Smell GAS Lighting Instructions Turning Off the Gas to the ApplianceValve in the on position Troubleshooting the Gas Control System Fuel Conversion Instructions SIT top Convertible PilotSIT 820 Nova Gas Control Valve Fig Maintenance Cleaning the Standing Pilot Control SystemBurner and Burner Compartment 36CDV DescriptionFuel Conversion Kits CDVFan Kits Optional Accessories AvailableWiring Instructions Remote ControlsCDV Series Direct Vent Gas Fireplace Product Covered by this Warranty Limited Lifetime WarrantyCFM Corporation