Vermont Casting 36CDVRRN, 36CDVTRN Installation & Operating Instructions, Locating Your Fireplace

Page 3

CDV Series Direct Vent Gas Fireplace

Installation & Operating Instructions

This gas appliance should be installed by a qualified installer in accordance with local building codes and with current CSA-B149.1 Installation codes for Gas Burning Appliances and Equipment. For USA Installations follow local codes and/or the current National Fuel Gas Code. ANSI Z223.1/NFPA 54.

In the Commonwealth of Massachusetts, all gas fitting and installation of this heater shall only be done by a licensed gas fitter or licensed plumber.

FOR SAFE INSTALLATION AND OPERATION PLEASE NOTE THE FOLLOWING:

1.This fireplace gives off high temperatures and should be located out of high traffic areas and away from furniture and draperies.

2.Children and adults should be alerted to the hazards of high surface temperatures of this fireplace and should stay away to avoid burns or ignition of clothing.

3.CAUTION: Due to high glass surface temperature chil- dren should be carefully supervised when in the same room as fireplace.

4.Under no circumstances should this fireplace be modified. Parts removed for servicing should be replaced prior to operating this fireplace again.

5.Installation and any repairs to this fireplace must be performed by a qualified installer, service agency or gas supplier. A professional service person should be contacted to inspect this fireplace annually. Make it a practice to have all of your gas fireplaces checked annually. More frequent cleaning may be required due to excess lint and dust from carpeting, bedding material, etc.

6.Control compartments, burners and air passages in this fireplace should be kept clean and free of dust and lint. Make sure the gas valve and pilot light are turned off before you attempt to clean this fireplace.

7.The venting system (chimney) of this fireplace should be checked at least once a year and if needed your venting system should be cleaned.

8.Keep the area around your fireplace clear of combustible materials, gasoline and other flammable vapor and liquids. This fireplace should not be used as a drying rack for cloth- ing, nor should Christmas stockings or decorations be hung on or around the fireplace.

9.Under no circumstances should any solid fuels (wood, coal, paper or cardboard etc.) be used in this fireplace.

10.The flow of combustion and ventilation air must not be obstructed in any way.

11.When fireplace is installed directly on carpeting, vinyl tile or any combustible material other than wood, the fireplace must be installed on a metal or wood panel extending the full width and depth of the fireplace.

12.This fireplace requires adequate ventilation and combustion air to operate properly.

13.This fireplace must not be connected to a chimney flue serving a separate solid fuel burning fireplace.

14.When the fireplace is not in use it is recommended that the gas valve be left in the OFF position.

15.These units have been approved for bedroom use.

Proposition 65 Warning: Fuels used in gas, wood- burning or oil fired appliances, and the products of combustion of such fuels, contain chemicals known to the State of California to cause cancer, birth defects and other reproductive harm.

California Health & Safety Code Sec. 25249.6

WARNING: Check with your electronics manufacturer before installing a television or other electronic de- vice above this fireplace.

IMPORTANT:

PLEASE REVIEW THE FOLLOWING CAREFULLY

Remove any plastic from trim parts before turning the fireplace ON.

It is normal for fireplaces fabricated of steel to give off some expansion and/or contraction noises during the start up or cool down cycle. Similar noises are found with your furnace heat exchanger or car engine.

It is not unusual for your gas fireplace to give off some odor the first time it is burned. This is due to the curing of the paint and any undetected oil from the manufacturing process.

Please ensure that your room is well ventilated - open all windows.

It is recommended that you burn your fireplace for at least ten (10) hours the first time you use it. If the optional fan kit has been installed, place the fan switch in the “OFF” position during this time.

Locating Your Fireplace

E

A

B

Y

 

 

 

 

C

X

 

 

D

 

 

Y

X

B

 

 

F

 

 

 

LU584-R

 

 

Fig. 1 Locate gas fireplace.

 

A) Flat on wall

B) Cross corner

C) **Island

D) *Room divider

E) *Flat on wall corner

F) Chase installation

Y) 6” minimum

 

 

NOTE: (Fig. 1)

**Island (C) and Room Divider (D) installation is possible as long as the horizontal portion of the vent system (X) does not exceed 20’ (6 m) with a minimum vertical of 4’ (122 cm). See details in Venting Section.

*When you install your fireplace in(D) Room divider or (E) Flat on wall corner positions (Y), a minimum of 6” (153 mm) clear- ance must be maintained from the perpendicular wall and the front side edge of the fireplace.

Refer to (Y) in Figure 1.

20010175

3

Image 3
Contents Builder Direct Vent Models Table of Contents Installation & Operating Instructions Locating Your FireplacePlease Review the Following Carefully Must be adhered to Fireplace Dimensions Rear VentFraming Dimensions 36CDVR36CDVT Fireplace Dimensions Top VentClearance to Combustibles MantelsHearth Gas Specifications Hood InstallationFraming and Finishing Final FinishingHigh Elevations Gas Line InstallationRemote ON/OFF Switch Gas Inlet and Manifold PressuresLocation of Vent Termination General VentingGeneral Venting Information Termination Location Canadian Installations1 US Installations2Flex Vent Pipes Canadian InstallationsUSA Installations General Information Assembling Vent PipesFrom Rear of Unit How to Use the Vent Graph36CDVR Venting Rear Wall Venting ApplicationsStep Rear Wall Installation Twist Lock PipeBend flex pipe up 90 as close to fireplace as pos- sible Rear Wall Vent Installations Flex Vent PipeSecure collar in place, slide termination into collar Vertical Sidewall ApplicationsMaximum horizontal vent run Vertical Sidewall InstallationAlways install hori- zontal venting on a level plane Vertical Through-the-Roof Applications Below Grade InstallationsEnlarged ends of the vent section always face downward. Fig Vertical Through-the-Roof Installation36CDVT Vertical Venting Typical straight-up installation+ B = 17 5.2m Max Always install horizontal venting on a level plane Vertical Sidewall InstallationsThrough the wall Example Maximum horizontal length Roof and ceiling supports Min 610 mm Venting Components Glass Information Glass CleaningWindow Frame Assembly Removal Operating InstructionsRN/RP & EN/EP Models Flame CharacteristicsFlame & Temperature Adjustment LogsLighting and Operating Instructions To Turn Off Gas to FireplaceWhat to do if YOU Smell GAS Lighting Instructions Turning Off the Gas to the ApplianceValve in the on position Troubleshooting the Gas Control System Fuel Conversion Instructions SIT top Convertible PilotSIT 820 Nova Gas Control Valve Fig Maintenance Cleaning the Standing Pilot Control SystemBurner and Burner Compartment 36CDV DescriptionFuel Conversion Kits CDVFan Kits Optional Accessories AvailableWiring Instructions Remote ControlsCDV Series Direct Vent Gas Fireplace Product Covered by this Warranty Limited Lifetime WarrantyCFM Corporation