Vermont Casting 36CDVTRN, 36CDVRRN Operating Instructions, Glass Information, Louvre Removal

Page 28

CDV Series Direct Vent Gas Fireplace

Operating Instructions

Glass Information

Only glass approved by CFM Corporation should be used on this fireplace.

The use of any non-approved replacement glass will void all product warranties.

Care must be taken to avoid breakage of the glass.

Do not operate appliance with glass front removed, cracked or broken.

Replacement glass (complete with gasket) is available through your CFM Corporation dealer and should only be installed by a licensed qualified service person.

Louvre Removal

Lower Clamps

 

Window

 

Frame

Window

Assembly

 

Frame

Pull Clamp

Assembly

Hook

Push

Clamp

 

The top louvre panel is removed by lifting the panel vertically and pulling it away from the appliance. (Fig. 56) The lower access door is removed in the same manner.

2.

Louvre

1.

Glass Panel

FP1602

Fig. 56 Remove top louvre assembly.

Handle

FP1228

 

Fig. 57 Window frame assembly removal.

Glass Cleaning

It is necessary to periodically clean glass. During start- up condensation, which is normal, forms on the inside of the glass. This condensation causes lint, dust and other airborne particles to cling to glass surface.

Also initial paint curing may deposit a slight film on the glass. It is therefore recommended the glass be cleaned two or three times with a non-ammonia based household cleaner and warm water (We recommend gas fireplace glass cleaner) within the first few weeks of operation.

Window Frame Assembly Removal

1.Turn the fireplace OFF (including the pilot)

2.If the unit has been operating allow time for the components to cool.

3.Remove the top louvre assembly.

4.Remove the lower louvre panel.

5.Release the two clamps securing the lower edge of the window frame assembly by pulling down on the handles. (Fig. 57)

6.Tilt the window frame assembly out slightly at the bottom, lift the window frame assembly up and away from the fireplace.

7.To replace the window frame assembly reverse the procedure.

After the initial cleaning process the glass should be cleaned two or three times during each operating season depending on the environment in the house.

Clean glass after first two weeks of operation.

Do not clean glass when hot.

Do not use abrasive cleaners.

Do not strike or slam the glass.

28

20010175

Image 28
Contents Builder Direct Vent Models Table of Contents Locating Your Fireplace Installation & Operating InstructionsPlease Review the Following Carefully Fireplace Dimensions Rear Vent Framing Dimensions36CDVR Must be adhered toFireplace Dimensions Top Vent 36CDVTMantels Clearance to CombustiblesHearth Hood Installation Framing and FinishingFinal Finishing Gas SpecificationsGas Line Installation Remote ON/OFF SwitchGas Inlet and Manifold Pressures High ElevationsGeneral Venting Location of Vent TerminationCanadian Installations1 US Installations2 General Venting Information Termination LocationCanadian Installations USA InstallationsGeneral Information Assembling Vent Pipes Flex Vent PipesHow to Use the Vent Graph 36CDVR VentingRear Wall Venting Applications From Rear of UnitRear Wall Installation Twist Lock Pipe StepRear Wall Vent Installations Flex Vent Pipe Bend flex pipe up 90 as close to fireplace as pos- sibleVertical Sidewall Applications Secure collar in place, slide termination into collarVertical Sidewall Installation Maximum horizontal vent runAlways install hori- zontal venting on a level plane Below Grade Installations Vertical Through-the-Roof ApplicationsVertical Through-the-Roof Installation Enlarged ends of the vent section always face downward. FigTypical straight-up installation 36CDVT Vertical Venting+ B = 17 5.2m Max Vertical Sidewall Installations Always install horizontal venting on a level planeThrough the wall Example Maximum horizontal length Roof and ceiling supports Min 610 mm Venting Components Glass Cleaning Window Frame Assembly RemovalOperating Instructions Glass InformationFlame Characteristics Flame & Temperature AdjustmentLogs RN/RP & EN/EP ModelsTo Turn Off Gas to Fireplace Lighting and Operating InstructionsWhat to do if YOU Smell GAS Turning Off the Gas to the Appliance Lighting InstructionsValve in the on position Troubleshooting the Gas Control System SIT top Convertible Pilot Fuel Conversion InstructionsSIT 820 Nova Gas Control Valve Fig Cleaning the Standing Pilot Control System MaintenanceBurner and Burner Compartment Description 36CDVCDV Fuel Conversion KitsOptional Accessories Available Wiring InstructionsRemote Controls Fan KitsCDV Series Direct Vent Gas Fireplace Limited Lifetime Warranty Product Covered by this WarrantyCFM Corporation