Vermont Casting 36CDVRRN, 36CDVTRN Lighting Instructions, Turning Off the Gas to the Appliance

Page 31

CDV Series Direct Vent Gas Fireplace

Lighting and Operating Instructions

For Fireplaces equipped with SIT822 Gas Valve (EN or EP) Warning:If you do not follow these instructions exactly, a fire or explosion

may result causing property damage, personal injury and loss of life.

FOR YOUR SAFETY READ THE FOLLOWING WARNINGS

BEFORE LIGHTING THE APPLIANCE

A.This fireplace is equipped with an ignition device which automatically lights the pilot. DO NOT try to light the pilot by hand.

B.BEFORE OPERATING, smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than the air and will settle on the floor.

What to do if you smell gas

Do not try to light any appliance

Do not operate any electrical switch.

Do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone.

Follow the gas suppliers instructions.

If you cannot contact your gas supplier call the Fire Department

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand do not try to repair it, call a qualified service technician. Force or attempting repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and replace any part of the control system and any gas control that has been under water.

Lighting Instructions

1.STOP! Read the safety information above before continuing.

2.Turn off all electrical power to the appliance.

3.This appliance is equipped with an ignition device which automatically lights the pilot. DO NOT try to light the pilot by hand.

4.Access the gas control by lowering the lower access door (louvre assembly).

HI

5.Turn the remote switch, if used, OFF. Turn the wireless remote, if used, OFF.

6.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas STOP. Follow instructions B in the safety warnings above. If you do not smell gas go onto the next step.

7.Close the access door.

8.Turn ON all electrical power to the appliance.

9.Turn remote switch or wireless remote to “ON”.

10.If the appliance will not operate, follow the instructions TURNING OFF THE GAS TO THE APPLIANCE and call your service technician or gas supplier.

Turning Off the Gas to the Appliance

1.Turn the remote switch to the “OFF” position.

2.Turn OFF all electrical power to the fireplace if service is required.

3 Open the lower access panel.

4.Turn the shut-off valve on the flexible gas line to the “OFF” position.

1/2” Gas Supply

1/2” NPT x 1/2” Flare Shut-Off

Valve

3/8” Flex Line

(From Valve)

Valve in the on position

20010175

31

Image 31
Contents Builder Direct Vent Models Table of Contents Locating Your Fireplace Installation & Operating InstructionsPlease Review the Following Carefully Must be adhered to Fireplace Dimensions Rear VentFraming Dimensions 36CDVR36CDVT Fireplace Dimensions Top VentMantels Clearance to CombustiblesHearth Gas Specifications Hood InstallationFraming and Finishing Final FinishingHigh Elevations Gas Line InstallationRemote ON/OFF Switch Gas Inlet and Manifold PressuresLocation of Vent Termination General VentingGeneral Venting Information Termination Location Canadian Installations1 US Installations2Flex Vent Pipes Canadian InstallationsUSA Installations General Information Assembling Vent PipesFrom Rear of Unit How to Use the Vent Graph36CDVR Venting Rear Wall Venting ApplicationsStep Rear Wall Installation Twist Lock PipeBend flex pipe up 90 as close to fireplace as pos- sible Rear Wall Vent Installations Flex Vent PipeSecure collar in place, slide termination into collar Vertical Sidewall ApplicationsMaximum horizontal vent run Vertical Sidewall InstallationAlways install hori- zontal venting on a level plane Vertical Through-the-Roof Applications Below Grade InstallationsEnlarged ends of the vent section always face downward. Fig Vertical Through-the-Roof Installation36CDVT Vertical Venting Typical straight-up installation+ B = 17 5.2m Max Always install horizontal venting on a level plane Vertical Sidewall InstallationsThrough the wall Example Maximum horizontal length Roof and ceiling supports Min 610 mm Venting Components Glass Information Glass CleaningWindow Frame Assembly Removal Operating InstructionsRN/RP & EN/EP Models Flame CharacteristicsFlame & Temperature Adjustment LogsTo Turn Off Gas to Fireplace Lighting and Operating InstructionsWhat to do if YOU Smell GAS Turning Off the Gas to the Appliance Lighting InstructionsValve in the on position Troubleshooting the Gas Control System SIT top Convertible Pilot Fuel Conversion InstructionsSIT 820 Nova Gas Control Valve Fig Cleaning the Standing Pilot Control System MaintenanceBurner and Burner Compartment 36CDV DescriptionFuel Conversion Kits CDVFan Kits Optional Accessories AvailableWiring Instructions Remote ControlsCDV Series Direct Vent Gas Fireplace Product Covered by this Warranty Limited Lifetime WarrantyCFM Corporation