Emerson 8712E manual Size Class, Code, Pound-feet

Page 10

Quick Installation Guide

Rosemount 8712 / 8700 Series

00825-0100-4664, Rev BB January 2013

If leakage has not stopped at the suggested torque values, the bolts can be tightened in additional 10% increments until the joint stops leaking, or until the measured torque value reaches the maximum torque value of the bolts. Practical consideration for the integrity of the liner often leads the user to distinct torque values to stop leakage due to the unique combinations of flanges, bolts, gaskets, and sensor liner material.

Check for leaks at the flanges after tightening the bolts. Failure to use the correct tightening methods can result in severe damage. Sensors require a second tightening 24 hours after the initial installation. Over time, sensor liner materials may deform under pressure.

Figure 7. Flange Bolt Torquing Sequence

1

8 5

4

8-bolt

3

 

 

 

67

2

Table 1. Suggested Flange Bolt Torque Values for Rosemount 8705 and 8707 High-Signal Sensors

 

 

PTFE/ETFE/PFA

Polyurethane/Neoprene/Linatex/Adiprene

 

 

liners

 

liner

Size

 

Class 150

Class 300

Class 150

 

Class 300

Code

Line Size

(pound-feet)

(pound-feet)

(pound-feet)

 

(pound-feet)

005

0.5 inch (15 mm)

8

8

-

 

-

010

1 inch (25 mm)

8

12

-

 

-

015

1.5 inch (40 mm)

13

25

7

 

18

020

2 inch (50 mm)

19

17

14

 

11

030

3 inch (80 mm)

34

35

23

 

23

040

4 inch (100 mm)

26

50

17

 

32

060

6 inch (150mm)

45

50

30

 

37

080

8 inch (200 mm)

60

82

42

 

55

100

10 inch (250 mm)

55

80

40

 

70

120

12 inch (300 mm)

65

125

55

 

105

140

14 inch (350 mm)

85

110

70

 

95

160

16 inch (400 mm)

85

160

65

 

140

180

18 inch (450 mm)

120

170

95

 

150

200

20 inch (500 mm)

110

175

90

 

150

240

24 inch (600 mm)

165

280

140

 

250

300

30 inch (750 mm)

195

415

165

 

375

360

36 inch (900 mm)

280

575

245

 

525

10

Image 10
Contents Quick Installation Guide Management Asia Pacific Private LimitedPRE-INSTALLATION Mechanical Considerations12.02 Dimensions are in inches millimeters109 305Hardware Jumpers/Switches Installation ProceduresIdentify Options and Configurations Environmental ConsiderationsHandling Electrical ConsiderationsFlow Direction MountingUpstream/Downstream Piping Sensor OrientationFlow Gaskets InstallationFlanged Sensors Flange BoltsCode Size ClassPound-feet Newton PTFE/ETFE liner PN10 SizeNewton Code Meter Polyurethane, Linatex, Adiprene and Neoprene Liners Size Alignment Wafer SensorsNominal Sensor Size Rosemount Alignment Spacer Table Line Size Dash No Alignment and Bolting Sanitary SensorsPound-feet Newton-meter Lining GroundingProcess Grounding Options Type of Pipe StrapsGrounding with Grounding Electrode Coil Drive and Electrode Cables Power Outputs WiringPower Outputs Conduit Ports and ConnectionsTransmitter to Sensor Wiring Remote Mount Cable Requirements and PreparationDescription Wiring the Transmitter to the SensorTransmitter Terminal Sensor Terminal Wire Gauge Wire Color Part NumberRemote Mount Wiring Diagrams External Power Source Connect the 4-20 mA Analog SignalInternal Power Source Cabling considerationsInstallation Category Powering the TransmitterSupply Wire Requirements DisconnectsAC Ground or DC Ground Transmitter Power Cable 8712E Power SupplyFuse Basic Setup Function Fast Keys Process Variables PV Basic SetupLocal Operator Interface ReviewEuropean Directive Information Product CertificationsApproved Manufacturing Locations International CertificatesInternational Certifications European Certifications N1 Atex Type nSpecial Conditions for Safe Use N7 IECEx Type nSensor Approval Information Rosemount 8705 and 8711 Sensors Meter Size Inches Maximum Ambient TemperatureMaximum Process EC Declaration of Conformity Schedule