Emerson 8712E manual Management Asia Pacific, Private Limited

Page 2

Quick Installation Guide

Rosemount 8712 / 8700 Series

00825-0100-4664, Rev BB January 2013

© 2013 Rosemount Inc. All rights reserved. All marks property of owner.

Emerson Process Management Emerson Process

Emerson FZE

Emerson Process

Rosemount Flow

Management Flow

P.O. Box 17033

Management Asia Pacific

7070 Winchester Circle,

Neonstraat 1

Jebel Ali Free Zone

Private Limited

Dubai UAE

Boulder, CO 80301

6718 WX Ede

1 Pandan Crescent

Tel (USA) 800 522 6277

The Netherlands

Tel +971 4 811 8100

Singapore 128461

Tel (International) +1 (303) 527 5200

T +31 (0)318 495555

Fax +971 4 886 5465

T (65) 6777

8211

Fax +1 (303) 530 8459

F +31(0) 318 495556

 

F (65) 6777

0947/65 6777 0743

IMPORTANT NOTICE

This document provides basic installation guidelines for the Rosemount® 8712. It does not provide instructions for detailed configuration, diagnostics, maintenance, service, troubleshooting, explosion-proof, flame-proof, or intrinsically safe (I.S.) installations. Refer to the Rosemount 8712 reference manual (document number 00809-0100-4664) for more instructions. The manual and this QIG are also available electronically on www.rosemount.com.

WARNING

Failure to follow these installation guidelines could result in death or serious injury:

Installation and servicing instructions are for use by qualified personnel only. Do not perform any servicing other than that contained in the operating instructions, unless qualified. Verify that the operating environment of the sensor and transmitter is consistent with the appropriate FM, CSA, ATEX, or IECEx approval.

Do not connect a Rosemount 8712 to a non-Rosemount sensor that is located in an explosive atmosphere.

WARNING

The sensor liner is vulnerable to handling damage. Never place anything through the sensor for the purpose of lifting or gaining leverage. Liner damage can render the sensor useless.

To avoid possible damage to the sensor liner ends, do not use metallic or spiral-wound gaskets. If frequent removal is anticipated, take precautions to protect the liner ends. Short spool pieces attached to the sensor ends are often used for protection.

Correct flange bolt tightening is crucial for proper sensor operation and life. All bolts must be tightened in the proper sequence to the specified torque limits. Failure to observe these instructions could result in severe damage to the sensor lining and possible sensor replacement.

2

Image 2
Contents Quick Installation Guide Management Asia Pacific Private LimitedPRE-INSTALLATION Mechanical Considerations12.02 Dimensions are in inches millimeters109 305Hardware Jumpers/Switches Installation ProceduresIdentify Options and Configurations Environmental ConsiderationsHandling Electrical ConsiderationsFlow Direction MountingUpstream/Downstream Piping Sensor OrientationFlow Gaskets InstallationFlanged Sensors Flange BoltsPound-feet Size ClassCode Newton Code Meter PTFE/ETFE liner PN10 SizeNewton Polyurethane, Linatex, Adiprene and Neoprene Liners Size Nominal Sensor Size Wafer SensorsAlignment Rosemount Alignment Spacer Table Line Size Dash No Pound-feet Newton-meter Sanitary SensorsAlignment and Bolting Lining GroundingProcess Grounding Options Type of Pipe StrapsGrounding with Grounding Electrode Coil Drive and Electrode Cables Power Outputs WiringPower Outputs Conduit Ports and ConnectionsTransmitter to Sensor Wiring Remote Mount Cable Requirements and PreparationDescription Wiring the Transmitter to the SensorTransmitter Terminal Sensor Terminal Wire Gauge Wire Color Part NumberRemote Mount Wiring Diagrams External Power Source Connect the 4-20 mA Analog SignalInternal Power Source Cabling considerationsInstallation Category Powering the TransmitterSupply Wire Requirements DisconnectsFuse 8712E Power SupplyAC Ground or DC Ground Transmitter Power Cable Basic Setup Function Fast Keys Process Variables PV Basic SetupLocal Operator Interface ReviewEuropean Directive Information Product CertificationsApproved Manufacturing Locations International CertificatesInternational Certifications European Certifications N1 Atex Type nSpecial Conditions for Safe Use N7 IECEx Type nSensor Approval Information Maximum Process Meter Size Inches Maximum Ambient TemperatureRosemount 8705 and 8711 Sensors EC Declaration of Conformity Schedule