Table 2. Flange Bolt Torque and Bolt Load Specifications for 8705(EN 1092-1)

 

 

 

 

 

PTFE/ETFE liner

 

 

 

 

 

PN10

PN 16

PN 25

PN 40

Size

Line Size

(Newton-

(Newton)

(Newton-

(Newton)

(Newton-

(Newton)

(Newton-

(Newton)

Code

meter)

meter)

meter)

meter)

005

0.5-inch

 

 

 

 

 

 

10

4400

 

(15 mm)

 

 

 

 

 

 

 

 

010

1 inch

 

 

 

 

 

 

20

10100

 

(25 mm)

 

 

 

 

 

 

 

 

015

1.5 inch

 

 

 

 

 

 

50

16100

 

(40 mm)

 

 

 

 

 

 

 

 

020

2 inch

 

 

 

 

 

 

60

20100

 

(50 mm)

 

 

 

 

 

 

 

 

030

3 inch

 

 

 

 

 

 

50

16800

 

(80 mm)

 

 

 

 

 

 

 

 

040

4 inch

 

 

50

17800

 

 

70

19600

 

(100 mm)

 

 

 

 

 

 

 

 

060

6 inch

 

 

90

24700

 

 

130

28700

 

(150mm)

 

 

 

 

 

 

 

 

080

8 inch

130

35200

90

19700

130

29200

170

34400

 

(200 mm)

 

 

 

 

 

 

 

 

100

10 inch

100

28000

130

28300

190

38000

250

44800

 

(250 mm)

 

 

 

 

 

 

 

 

120

12 inch

120

32000

170

38400

190

38600

270

47700

 

(300 mm)

 

 

 

 

 

 

 

 

140

14 inch

160

43800

220

49500

320

57200

410

68100

 

(350 mm)

 

 

 

 

 

 

 

 

160

16 inch

220

50600

280

56200

410

68100

610

92900

 

(400 mm)

 

 

 

 

 

 

 

 

180

18 inch

190

43200

340

68400

330

55100

420

64000

 

(450 mm)

 

 

 

 

 

 

 

 

200

20 inch

230

51100

380

68900

440

73300

520

73900

 

(500 mm)

 

 

 

 

 

 

 

 

240

24 inch

290

58600

570

93600

590

90100

850

112000

 

(600 mm)

 

 

 

 

 

 

 

 

11

Image 11
Contents Quick Installation Guide Private Limited Management Asia PacificMechanical Considerations PRE-INSTALLATION305 Dimensions are in inches millimeters109 12.02Environmental Considerations Installation ProceduresIdentify Options and Configurations Hardware Jumpers/SwitchesElectrical Considerations HandlingSensor Orientation MountingUpstream/Downstream Piping Flow DirectionFlow Flange Bolts InstallationFlanged Sensors GasketsPound-feet Size ClassCode Newton Code Meter PTFE/ETFE liner PN10 SizeNewton Polyurethane, Linatex, Adiprene and Neoprene Liners Size Nominal Sensor Size Wafer SensorsAlignment Rosemount Alignment Spacer Table Line Size Dash No Pound-feet Newton-meter Sanitary SensorsAlignment and Bolting Straps GroundingProcess Grounding Options Type of Pipe LiningGrounding with Grounding Electrode Conduit Ports and Connections WiringPower Outputs Coil Drive and Electrode Cables Power OutputsRemote Mount Cable Requirements and Preparation Transmitter to Sensor WiringPart Number Wiring the Transmitter to the SensorTransmitter Terminal Sensor Terminal Wire Gauge Wire Color DescriptionRemote Mount Wiring Diagrams Cabling considerations Connect the 4-20 mA Analog SignalInternal Power Source External Power SourceDisconnects Powering the TransmitterSupply Wire Requirements Installation CategoryFuse 8712E Power SupplyAC Ground or DC Ground Transmitter Power Cable Basic Setup Review Basic SetupLocal Operator Interface Function Fast Keys Process Variables PVInternational Certificates Product CertificationsApproved Manufacturing Locations European Directive InformationN7 IECEx Type n European Certifications N1 Atex Type nSpecial Conditions for Safe Use International CertificationsSensor Approval Information Maximum Process Meter Size Inches Maximum Ambient TemperatureRosemount 8705 and 8711 Sensors EC Declaration of Conformity Schedule