Emerson 8712E manual Rosemount Alignment Spacer Table Line Size Dash No

Page 14

Quick Installation Guide

Rosemount 8712 / 8700 Series

00825-0100-4664, Rev BB January 2013

Table 4. Rosemount Alignment Spacer Table

Rosemount Alignment Spacer Table

Line Size

Dash No.

 

 

Flange Rating

(in)

(mm)

0A15

1.5

40

JIS 10K-20K

0A20

2

50

JIS 10K-20K

0A30

3

80

JIS 10K

0B15

1.5

40

JIS 40K

AA15

1.5

40

ANSI - 150#

AA20

2

50

ANSI - 150#

AA30

3

80

ANSI - 150#

AA40

4

100

ANSI - 150#

AA60

6

150

ANSI - 150#

AA80

8

200

ANSI - 150#

AB15

1.5

40

ANSI - 300#

AB20

2

50

ANSI - 300#

AB30

3

80

ANSI - 300#

AB40

4

100

ANSI - 300#

AB60

6

150

ANSI - 300#

AB80

8

200

ANSI - 300#

AB15

1.5

40

ANSI - 300#

AB20

2

50

ANSI - 300#

AB30

3

80

ANSI - 300#

AB40

4

100

ANSI - 300#

AB60

6

150

ANSI - 300#

AB80

8

200

ANSI - 300#

DB40

4

100

DIN - PN10/16

DB60

6

150

DIN - PN10/16

DB80

8

200

DIN - PN10/16

DC80

8

100

DIN - PN25

DD15

1.5

150

DIN - PN10/16/25/40

DD20

2

50

DIN - PN10/16/25/40

DD30

3

80

DIN - PN10/16/25/40

DD40

4

100

DIN - PN25/40

DD60

6

150

DIN - PN25/40

DD80

8

200

DIN - PN40

RA80

8

200

AS40871-PN16

RC20

2

50

AS40871-PN21/35

RC30

3

80

AS40871-PN21/35

RC40

4

100

AS40871-PN21/35

RC60

6

150

AS40871-PN21/35

RC80

8

200

AS40871-PN21/35

To order an Alignment Spacer Kit (qty 3 spacers) use p/n 08711-3211-xxxx along with the Dash No. above.

14

Image 14
Contents Quick Installation Guide Management Asia Pacific Private LimitedPRE-INSTALLATION Mechanical Considerations12.02 Dimensions are in inches millimeters109 305Hardware Jumpers/Switches Installation ProceduresIdentify Options and Configurations Environmental ConsiderationsHandling Electrical ConsiderationsFlow Direction MountingUpstream/Downstream Piping Sensor OrientationFlow Gaskets InstallationFlanged Sensors Flange BoltsPound-feet Size ClassCode Newton Code Meter PTFE/ETFE liner PN10 SizeNewton Polyurethane, Linatex, Adiprene and Neoprene Liners Size Nominal Sensor Size Wafer SensorsAlignment Rosemount Alignment Spacer Table Line Size Dash No Pound-feet Newton-meter Sanitary SensorsAlignment and Bolting Lining GroundingProcess Grounding Options Type of Pipe StrapsGrounding with Grounding Electrode Coil Drive and Electrode Cables Power Outputs WiringPower Outputs Conduit Ports and ConnectionsTransmitter to Sensor Wiring Remote Mount Cable Requirements and PreparationDescription Wiring the Transmitter to the SensorTransmitter Terminal Sensor Terminal Wire Gauge Wire Color Part NumberRemote Mount Wiring Diagrams External Power Source Connect the 4-20 mA Analog SignalInternal Power Source Cabling considerationsInstallation Category Powering the TransmitterSupply Wire Requirements DisconnectsFuse 8712E Power SupplyAC Ground or DC Ground Transmitter Power Cable Basic Setup Function Fast Keys Process Variables PV Basic SetupLocal Operator Interface ReviewEuropean Directive Information Product CertificationsApproved Manufacturing Locations International CertificatesInternational Certifications European Certifications N1 Atex Type nSpecial Conditions for Safe Use N7 IECEx Type nSensor Approval Information Maximum Process Meter Size Inches Maximum Ambient TemperatureRosemount 8705 and 8711 Sensors EC Declaration of Conformity Schedule