Schedule

EC Declaration of Conformity RMD 1031 Rev. E

LVD Directive (2006/95/EC)

All Models

EN 61010-1: 2001

EMC Directive (2004/108/EC)

All Models

EN 61326-1: 2006

ATEX Directive (94/9/EC)

Model 8712D with Power Supply Option “03” and option code “N1”

Model 8712E with Power Supply Option “2” and option code “N1”

Baseefa05ATEX0170X – Type n Certificate

Equipment Group II, Category 3 G (EEx nA nL IIC T4)

EN 60079-15: 2003

ATEX Notified Bodies for EC Type Examination Certificate

Baseefa [Notified Body Number: 1180]

Rockhead Business Park, Staden Lane

Buxton, Derbyshire SK17 9RZ

United Kingdom

ATEX Notified Body for Quality Assurance

Det Norske Veritas (DNV) [Notified Body Number: 0575]

Veritasveien 1, N-1322

Hovik, Norway

FILE ID: 8712 CE Marking

Page 2 of 2

8712_RMD1031E.DOC

32

Image 32
Contents Quick Installation Guide Management Asia Pacific Private LimitedPRE-INSTALLATION Mechanical ConsiderationsDimensions are in inches millimeters 10912.02 305Installation Procedures Identify Options and ConfigurationsHardware Jumpers/Switches Environmental ConsiderationsHandling Electrical ConsiderationsMounting Upstream/Downstream PipingFlow Direction Sensor OrientationFlow Installation Flanged SensorsGaskets Flange BoltsPound-feet Size ClassCode Newton Code Meter PTFE/ETFE liner PN10 SizeNewton Polyurethane, Linatex, Adiprene and Neoprene Liners Size Nominal Sensor Size Wafer SensorsAlignment Rosemount Alignment Spacer Table Line Size Dash No Pound-feet Newton-meter Sanitary SensorsAlignment and Bolting Grounding Process Grounding Options Type of PipeLining StrapsGrounding with Grounding Electrode Wiring Power OutputsCoil Drive and Electrode Cables Power Outputs Conduit Ports and ConnectionsTransmitter to Sensor Wiring Remote Mount Cable Requirements and PreparationWiring the Transmitter to the Sensor Transmitter Terminal Sensor Terminal Wire Gauge Wire ColorDescription Part NumberRemote Mount Wiring Diagrams Connect the 4-20 mA Analog Signal Internal Power SourceExternal Power Source Cabling considerationsPowering the Transmitter Supply Wire RequirementsInstallation Category DisconnectsFuse 8712E Power SupplyAC Ground or DC Ground Transmitter Power Cable Basic Setup Basic Setup Local Operator InterfaceFunction Fast Keys Process Variables PV ReviewProduct Certifications Approved Manufacturing LocationsEuropean Directive Information International CertificatesEuropean Certifications N1 Atex Type n Special Conditions for Safe UseInternational Certifications N7 IECEx Type nSensor Approval Information Maximum Process Meter Size Inches Maximum Ambient TemperatureRosemount 8705 and 8711 Sensors EC Declaration of Conformity Schedule