Emerson 8712E manual Rosemount 8705 and 8711 Sensors, Maximum Process

Page 30

Quick Installation Guide

Rosemount 8712 / 8700 Series

00825-0100-4664, Rev BB January 2013

Table 12. Electrical Data

Rosemount 8705 and 8711 Sensors

 

 

 

 

Coil excitation circuit:

40 V DC (pulsed), 0,5 A, 20 W maximum

 

 

 

Electrode circuit:

in type of explosion protection intrinsic safety EEx ia IIC, Ui

= 5 V, li = 0.2 mA,

 

 

Pi = 1 mW, Um = 250 V

 

 

 

 

Table 13. Relation between ambient temperature, process temperature, and temperature class(1)

 

 

 

Maximum Process

 

Temperature

Meter Size (Inches)

 

Maximum Ambient Temperature

Temperature

 

Class

1/2

 

115 °F (65 °C)

239 °F (115 °C)

 

T3

1

 

149 °F (65 °C)

248

°F (120 °C)

 

T3

1

 

95 °F (35 °C)

95

°F (35 °C)

 

T4

11/2

 

149 °F (65 °C)

257

°F (125 °C)

 

T3

11/2

 

122 °F (50 °C)

148 °F (60 °C)

 

T4

2

 

149 °F (65 °C)

257

°F (125 °C)

 

T3

2

 

149 °F (65 °C)

167 °F (75 °C)

 

T4

2

 

104 °F (40 °C)

104 °F (40 °C)

 

T5

3 - 36

 

149 °F (65 °C)

266

°F (130 °C)

 

T3

3 - 36

 

149 °F (65 °C)

194 °F (90 °C)

 

T4

3 - 36

 

131 °F (55 °C)

131 °F (55 °C)

 

T5

3 - 36

 

104 °F (40 °C)

104 °F (40 °C)

 

T6

6

 

115 °F (65 °C)

275 °F(135 °C)

 

T3

6

 

115 °F (65 °C)

230 °F (110 °C)

 

T4

6

 

115 °F (65 °C)

167 °F (75 °C)

 

T5

6

 

140 °F (60 °C)

140 °F (60 °C)

 

T6

8-60

 

115 °F (65 °C)

284

°F (140 °C)

 

T3

8-60

 

115 °F (65 °C)

239 °F (115 °C)

 

T4

8-60

 

115 °F (65 °C)

176 °F (80 °C)

 

T5

8-60

 

115 °F (65 °C)

145 °F (65 °C)

 

T6

(1)This table is applicable for KD approval codes only.

30

Image 30
Contents Quick Installation Guide Management Asia Pacific Private LimitedPRE-INSTALLATION Mechanical Considerations12.02 Dimensions are in inches millimeters109 305Hardware Jumpers/Switches Installation ProceduresIdentify Options and Configurations Environmental ConsiderationsHandling Electrical ConsiderationsFlow Direction MountingUpstream/Downstream Piping Sensor OrientationFlow Gaskets InstallationFlanged Sensors Flange BoltsSize Class CodePound-feet PTFE/ETFE liner PN10 Size NewtonNewton Code Meter Polyurethane, Linatex, Adiprene and Neoprene Liners Size Wafer Sensors AlignmentNominal Sensor Size Rosemount Alignment Spacer Table Line Size Dash No Sanitary Sensors Alignment and BoltingPound-feet Newton-meter Lining GroundingProcess Grounding Options Type of Pipe StrapsGrounding with Grounding Electrode Coil Drive and Electrode Cables Power Outputs WiringPower Outputs Conduit Ports and ConnectionsTransmitter to Sensor Wiring Remote Mount Cable Requirements and PreparationDescription Wiring the Transmitter to the SensorTransmitter Terminal Sensor Terminal Wire Gauge Wire Color Part NumberRemote Mount Wiring Diagrams External Power Source Connect the 4-20 mA Analog SignalInternal Power Source Cabling considerationsInstallation Category Powering the TransmitterSupply Wire Requirements Disconnects8712E Power Supply AC Ground or DC Ground Transmitter Power CableFuse Basic Setup Function Fast Keys Process Variables PV Basic SetupLocal Operator Interface ReviewEuropean Directive Information Product CertificationsApproved Manufacturing Locations International CertificatesInternational Certifications European Certifications N1 Atex Type nSpecial Conditions for Safe Use N7 IECEx Type nSensor Approval Information Meter Size Inches Maximum Ambient Temperature Rosemount 8705 and 8711 SensorsMaximum Process EC Declaration of Conformity Schedule