Emerson 8712E manual Product Certifications, Approved Manufacturing Locations

Page 27

Quick Installation Guide

00825-0100-4664, Rev BB January 2013

Rosemount 8712 / 8700 Series

PRODUCT CERTIFICATIONS

Approved Manufacturing Locations

Rosemount Inc. — Eden Prairie, Minnesota, USA

Fisher-Rosemount Technologias de Flujo, S.A. de C.V. — Chihuahua Mexico Emerson Process Management Flow — Ede, The Netherlands

Asia Flow Technology Center — Nanjing, China

European Directive Information

The EC declaration of conformity can be found on page 31. The most recent revision can be found at www.rosemount.com.

Type n protection type in accordance with EN 50021

• Closing of entries in the device must be carried out using the appropriate EExe or EExn metal cable gland and metal blanking plug or any appropriate ATEX approved cable gland and blanking plug with IP66 rating certified by an EU approved certification body.

CE Marking

Complies with EN 61326-1: 2006

Complies with Essential Health and Safety Requirements:

EN 60079-15: 2003

International Certificates

C-Tick Marking

Rosemount Inc. complies with the following IEC Requirements:

IEC 60079-0: 2004

IEC 60079-15: 2005-03

Hazardous Locations Certifications

North American Certifications

Factory Mutual (FM)

N0 Non-incendive for Class I, Division 2 Groups A, B, C, and D non-flammable fluids (T4 at 40 °C)

Dust-ignition proof Class II/III, Division 1 Groups E, F, and G

(T4 at 40 °C)

Hazardous Locations; Enclosure Type 4X, IP66

N5 Non-incendive for Class I, Division 2,

 

Groups A, B, C, and D flammable fluids

 

(T4 at 40 °C)

 

Dust-ignition proof Class II/III, Division 1

 

Groups E, F, and G

 

(T4 at 40 °C)

 

Hazardous Locations; Enclosure Type 4X, IP66

27

Requires sensors with N5 Approval

Image 27
Contents Quick Installation Guide Private Limited Management Asia PacificMechanical Considerations PRE-INSTALLATION305 Dimensions are in inches millimeters109 12.02Environmental Considerations Installation ProceduresIdentify Options and Configurations Hardware Jumpers/SwitchesElectrical Considerations HandlingSensor Orientation MountingUpstream/Downstream Piping Flow DirectionFlow Flange Bolts InstallationFlanged Sensors GasketsSize Class CodePound-feet PTFE/ETFE liner PN10 Size NewtonNewton Code Meter Polyurethane, Linatex, Adiprene and Neoprene Liners Size Wafer Sensors AlignmentNominal Sensor Size Rosemount Alignment Spacer Table Line Size Dash No Sanitary Sensors Alignment and BoltingPound-feet Newton-meter Straps GroundingProcess Grounding Options Type of Pipe LiningGrounding with Grounding Electrode Conduit Ports and Connections WiringPower Outputs Coil Drive and Electrode Cables Power OutputsRemote Mount Cable Requirements and Preparation Transmitter to Sensor WiringPart Number Wiring the Transmitter to the SensorTransmitter Terminal Sensor Terminal Wire Gauge Wire Color DescriptionRemote Mount Wiring Diagrams Cabling considerations Connect the 4-20 mA Analog SignalInternal Power Source External Power SourceDisconnects Powering the TransmitterSupply Wire Requirements Installation Category8712E Power Supply AC Ground or DC Ground Transmitter Power CableFuse Basic Setup Review Basic SetupLocal Operator Interface Function Fast Keys Process Variables PVInternational Certificates Product CertificationsApproved Manufacturing Locations European Directive InformationN7 IECEx Type n European Certifications N1 Atex Type nSpecial Conditions for Safe Use International CertificationsSensor Approval Information Meter Size Inches Maximum Ambient Temperature Rosemount 8705 and 8711 SensorsMaximum Process EC Declaration of Conformity Schedule