6Troubleshooting

 

Troubleshooting ATM-PNC

6-20

Table 6-8. Troubleshooting 400A T1 synchronization (through a DSU/CSU) —

 

 

 

 

 

Step Action

Description

 

 

 

 

 

15.If the 316X CSU or DSU/CSU fails the DTE or RLB loopback tests

Remove the H600-307 DS1 cable from the splitter and the splitter from the DS1 circuit pack

 

16.

Remove splitter

Remove the splitter from the DS1 circuit pack

 

 

17.

Reconnect the cable

Reconnect the H600-307 cable directly to the DS1 circuit

 

 

 

 

pack

 

 

 

 

After about 30 s, all the alarm LEDs on the 316X DSU/CSU

 

 

 

 

should go out.

 

 

 

 

If the alarm LEDs on the 316X CSU or DSU/CSU do not go

 

 

 

 

out, go to step 19.

 

 

 

 

 

 

 

18.

Test circuit pack

Test the DS1 circuit pack (test board UUCSS).

 

 

 

 

If any one of Test 138 through 145 fails, follow the repair

 

 

 

 

procedures listed in DEFINITY ECS Maintenance for R8r.

 

 

 

 

 

 

 

19.

Check for errors

Wait 15 minutes and check that the list measurements

 

 

 

 

ds1 summary UUCSS report is free of any errors. Use

 

 

 

 

Table 3-6 to help interpret the report.

 

 

 

 

 

 

 

20.

Replace the splitter

If the alarm LEDs on the 316X are not lit, replace the

 

 

 

 

splitter. If the splitter has already been replaced, escalate

 

 

 

 

to Tier 3.

 

 

 

 

 

 

 

21.

Test the DS1 circuit

If the alarm LEDs on the 316X extinguish with the new

 

 

 

pack

splitter installed, perform a test board UUCSS and press

 

 

 

 

Enter and verify that the DS1 circuit pack passes tests 138

 

 

 

 

through 145.

 

 

 

 

If any one of Test 138 through 145 fails, follow the repair

 

 

 

 

procedures listed in DEFINITY ECS Maintenance for R8r.

 

 

 

 

 

 

 

22.

Check error report

Wait 15 minutes and perform a list measurements ds1

 

 

 

 

summary UUCSS and verify that the DS1 circuit pack is

 

 

 

 

free of errors. Use Table 3-6 to help interpret the report.

 

 

 

 

 

 

 

23.

Release circuit pack

If there are no errors in step 22, release the DS1 circuit

 

 

 

 

pack (release board UUCSS).

 

 

 

 

 

 

 

24.

If the alarm LEDs on

Reseat the DS1 circuit pack.

 

 

 

the 316X fail to go out

 

 

 

 

 

 

 

 

25.

Escalate if necessary

If step 24 still fails, escalate to Tier 3

 

 

 

 

 

 