DEFINITY ECS Release 8.2 ATM Installation,

Issue 1

Upgrades, and Administration 555-233-124

April 2000

 

 

6Troubleshooting

 

 

Troubleshooting ATM-PNC

6-18

Table 6-7. Troubleshooting 400A synchronization (through an ICSU) —

 

 

 

 

 

 

 

 

Step

Action

Description

 

 

 

 

 

 

 

 

3.

Reseat circuit pack

Reseat the DS1 circuit pack.

 

 

 

 

 

 

 

 

4.

Retest the circuit

Repeat the test (test board UUCSS).

 

 

 

pack

If Tests 138 through 145 pass, go to step 14 (release).

 

 

 

 

 

 

 

 

If any test fails, go to step 5.

 

 

 

 

 

 

 

 

5.

Busyout the DS1

To suppress alarms on the DS1 circuit pack, type busyout

 

 

 

circuit pack

board UUCSS and press Enter.

 

 

 

 

 

 

 

 

6.

Remove ICSU

Remove the ICSU module from the splitter.

 

 

 

 

 

 

 

 

7.

Remove splitter

Remove the splitter from the DS1 circuit pack.

 

 

 

 

 

 

 

 

8.

Put ICSU directly on

Reconnect the ICSU module directly to the back of the

 

 

 

DS1 circuit pack

DS1 circuit pack (without the splitter) and reseat the DS1

 

 

 

 

circuit pack.

 

 

 

 

After approximately 30 seconds the DS1 Status LEDs

 

 

 

 

should extinguish, leaving only the green Status 3 LED on

 

 

 

 

steady.

 

 

 

 

 

 

 

 

9.

Test the circuit pack

Test the circuit pack (test board UUCSS) and verify that

 

 

 

 

the DS1 circuit pack passes Tests 138 through 145.

 

 

 

 

If any one of Test 138 through 145 fails, follow the repair

 

 

 

 

procedures listed in DEFINITY ECS Maintenance for R8r.

 

 

 

 

 

 

 

 

10.

Replace splitter

If the tests pass, replace the splitter onto the back of the

 

 

 

 

DS1 circuit pack.

 

 

 

 

 

 

 

 

11.

Reseat the circuit

Reseat the DS1 circuit pack and check the Amphenol

 

 

 

pack

connectors, making sure they are seated properly.

 

 

 

 

 

 

 

 

12.

Test the circuit pack

Test the circuit pack (test board UUCSS) and verify that

 

 

 

 

the DS1 circuit pack passes Tests 138 through 145.

 

 

 

 

If any one of Test 138 through 145 fails, follow the repair

 

 

 

 

procedures listed in DEFINITY ECS Maintenance for R8r or

 

 

 

 

replace the splitter.

 

 

 

 

 

 

 

 

13.

Escalate if necessary

If the ICSU tests OK, go to step 14.

 

 

 

 

If step 12 still fails, escalate to Tier 3 or replace the splitter.

 

 

 

 

 

 

 

 

14.

Release the circuit

Release the DS1 circuit pack (release board UUCSS).

 

 

 

pack

 

 

 

 

 

 

 

 

 

 

 

15.

Verify active

Verify that the designated DS1 circuit pack is now the

 

 

 

synchronization

active sync source (status synchronization).

 

 

 

source

 

 

 

 

 

 

 

 

 

 

Page 152
Image 152
Lucent Technologies Comcode 108678723 manual Troubleshooting 400A synchronization through an Icsu