Lucent Technologies Comcode 108678723 manual TN2305/TN2306 circuit pack

Models: Comcode 108678723

1 230
Download 230 pages 18.93 Kb
Page 143
Image 143

DEFINITY ECS Release 8.2 ATM Installation,

Issue 1

Upgrades, and Administration 555-233-124

April 2000

 

 

6Troubleshooting

 

 

Troubleshooting ATM-CES

6-9

Table 6-5. Troubleshooting CES —

 

 

 

 

 

 

 

 

 

 

 

 

 

Step

Action

Description

 

 

 

 

 

 

 

 

 

7.

Check D-channel

 

The D-channel is administered in a port numbered

 

 

 

administration

 

009–032 (display signaling-group siggrpnbr, screen 2).

 

 

 

 

 

 

NOTE:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The D-channel is automatically populated in

 

 

 

 

 

 

channel 24 (T1) and channel 16 (E1) and this must

 

 

 

 

 

 

match on both ends.

 

 

 

 

 

 

 

 

8.

Check trunk limits

DEFINITY trunk limits must not be exceeded (see Table

 

 

 

 

6-6)

 

 

 

 

 

 

 

 

 

 

 

Table 6-6. DEFINITY ECS trunk capacities by model

 

Capacity

c, csi, si

r

 

 

Maximum trunks per trunk group

99

255

 

 

 

 

 

 

 

Maximum number of trunk groups

99

666

 

 

 

 

 

 

 

Maximum number of trunks in the system

400

4000

 

 

 

 

 

 

NOTE:

Port numbers on each end of the emulated circuit do not have to match.

Is the ATM switch administered correctly?

To verify that a specific Lucent ATM switch was administered correctly, refer to the appropriate reference guide.

TN2305/TN2306 circuit pack

Did the TN2305/TN2306 come up correctly?

1.Review the LED conditions for the TN2305/TN2306 (refer to the appropriate maintenance book for LED indications):

Do the TN2305/TN2306 LEDs indicate a normal operational state (any of the following):

Active in the PPN

Standby in the PPN

Archangel mode in the EPN

Page 143
Image 143
Lucent Technologies Comcode 108678723 manual TN2305/TN2306 circuit pack, Is the ATM switch administered correctly?