Lucent Technologies Comcode 108678723 manual Interpretation of the list measurements report

Models: Comcode 108678723

1 230
Download 230 pages 18.93 Kb
Page 54
Image 54

DEFINITY ECS Release 8.2 ATM Installation,

Issue 1

Upgrades, and Administration 555-233-124

April 2000

 

 

3Installing a DEFINITY ECS ATM-PNC

 

Synchronization Installation and Testing

3-18

Table 3-6. Interpretation of the list measurements report

 

 

 

 

 

 

 

Displayed

 

 

 

 

 

Field

Function

Indication

 

 

 

 

 

Test:

3-in-24 stress

The loopback jack test is active

 

cpe-loopbac

test pattern

 

 

 

 

k-jack

 

 

 

 

 

 

 

 

 

Synchronize

= Y

The DS1 circuit pack is synchronized to the looped

 

d

 

3-in-24 pattern and is counting the bit errors detected

 

 

 

in the pattern until the test is ended.

 

 

= N

Retry the test:

 

 

 

1.

Stop the test (test ds1-loop UUCSS end

 

 

 

 

cpe-loopback-jack-test).

 

 

 

2.

Restart the test (test ds1-loopUUCSS

 

 

 

 

cpe-loopback-jack-test-begin)

 

 

 

3.

Repeat Steps 1 and 2 a maximum of 5 times, as

 

 

 

 

necessary.

 

 

 

If the circuit pack never synchronizes, it is possibly

 

 

 

due to intermittent connections or a broken wire in a

 

 

 

receive or transmit wire pair.

 

 

 

Bit Error

Cumulative

0 indicates that there are no wiring problems.

Count

detected

A count that sits at 65535 or continues to increment

 

 

errors

 

 

by several hundred to several thousand errors with

 

 

 

 

 

 

each subsequent list measurements command

 

 

 

indicates

 

 

 

Intermittent or corroded connections

 

 

 

Severe crosstalk

 

 

 

Impedance imbalances between the two

 

 

 

 

conductors of the receive or the transmit pairs.

 

 

 

1.

Replace wiring, if necessary.

 

 

 

2.

Note whether the Extended Super Frame (ESF)

 

 

 

 

error and performance counters summaries

 

 

 

 

(errored seconds, bursty errored seconds, and so

 

 

 

 

forth) also increment. Although these counters are

 

 

 

 

not used with the loopback jack test, they do

 

 

 

 

increment as errors occur.

 

 

 

 

 

 