Lucent Technologies Comcode 108678723 manual Testing the 120A 2 Icsu

Models: Comcode 108678723

1 230
Download 230 pages 18.93 Kb
Page 60
Image 60

DEFINITY ECS Release 8.2 ATM Installation,

Issue 1

Upgrades, and Administration 555-233-124

April 2000

3 Installing a DEFINITY ECS ATM-PNC

 

Synchronization Installation and Testing

3-24

 

 

Use the procedures in Table 3-11 to test the 120A ICSU with the 700A DS1 CPE loopback jack.

Table 3-11. Testing the 120A 2 ICSU

 

Step

Action

Command

Description

 

 

 

 

 

 

 

 

 

 

1.

Busyout the

busyout board

Busyout the DS1 circuit pack.

 

 

 

 

DS1 circuit pack

UUCSS

 

 

 

 

 

 

 

 

 

 

 

2.

Start the CPE

test ds1-loop

Start the CPE loopback test.

 

 

 

 

loopback test

UUCSS

If the test passes, the splitter is functioning

 

 

 

 

 

cpe-loopback-

 

 

 

 

 

properly; go to Step 3.

 

 

 

 

 

jack-test-begin

 

 

 

 

 

If the test fails, follow the procedures in

 

 

 

 

 

 

 

 

 

 

 

 

‘‘Troubleshooting synchronization (400A

 

 

 

 

 

 

only)’’ on page 6-17.

 

 

 

 

 

 

 

 

 

 

3.

Terminate the

test ds1-loop

Terminate the test .

 

 

 

 

test

UUCSS

 

 

 

 

 

 

end-loopback/

 

 

 

 

 

 

span-test

 

 

 

 

 

 

 

 

 

 

 

4.

Release the

release board

Release the DS1 circuit pack .

 

 

 

 

DS1 circuit pack

UUCSS

 

 

 

 

 

 

 

 

 

 

 

5.

Reassign

change

Reassign sync to the designated DS1 circuit pack .

 

 

 

 

synchronization

synchronization

 

 

 

 

 

 

 

 

 

Connected through a DSU/CSU. Before connecting any of the timing hardware, ensure that the DSU/CSU is configured to report loss of signal alarms.

If using a 316X CSU connected to a T1 facility and used as the DEFINITY synchronization source, verify or change the 316X settings (options) to ensure that it sends an AIS blue alarm to the DEFINITY ECS DS1 circuit pack or to the ATM switch whenever a network LOS (loss of signal) occurs. Upon receiving a LOS, the DEFINITY ECS or ATM switch transfers to its backup synchronization source.

Page 60
Image 60
Lucent Technologies Comcode 108678723 manual Testing the 120A 2 Icsu, ‘‘Troubleshooting synchronization 400A Only’’ on