Table 5-15. ATM-CES installation test procedure

 

 

 

 

 

 

 

 

What to check

How to check

How to fix

 

 

 

 

 

1.Check SONET/SDH layer for status and alarms.

2.Check the LEDs on the ATM circuit packs

3.Temporarily disable any call overflows through administration across each CES trunk group.

4.Ensure CDR records properly, if enabled

5.Verify that ISDN features are working

Refer to the maintenance book for descriptions of the LEDs, their flash rates, and the conditions indicated.

Place test call to any EPN remoted through each signaling group. Make sure call completes and has a 2-way talk path.