1Preparing for Installation and Upgrades

Review Configuration and Equipment

1-4

Required Hardware

Table 1-1 lists the required equipment for standard, high, critical reliability, and

ATM network duplication configurations.

Table 1-1. Minimum required equipment for Release 8 ATM-PNC configurations

 

 

 

 

Reliability level

 

 

 

 

 

 

Critical/ATM

 

 

Equipment

Standard

High

Network Duplication

 

 

 

 

 

 

 

 

 

ATM switch

1

1

 

2

 

 

 

 

 

 

 

 

TN2305/TN2306 ATM interface1

1

12

2

 

 

for each PN

 

 

 

 

 

 

 

 

 

 

 

 

 

T1 or E1 synchronization splitter3

1

1

 

1

 

 

SC-connected fiber optic cable4

1

2

(PPN)

2

 

 

 

 

1

(each EPN)

 

 

 

 

 

 

 

 

 

 

TN771 maintenance/test circuit

 

 

 

1

 

 

pack5

 

 

 

 

 

 

 

 

 

 

 

 

1.TN2305 (multimode fiber); TN2306 (single-mode fiber) for Release 8 ATM-PNC.

2.High reliability requires 2 ATM-EI circuit packs in the PPN and 1 ATM-EI in each EPN.

3.The number and uses of the synchronization splitter depend on the configuration and the source(s) from which primary and secondary synchronization is derived. You may need 1 sync splitter per ATM switch. DS1 synchronization requires either no sync splitter or up to a number twice the number of sites.

4.Existing fiber optic cable may require an ST-to-SC adapter, depending on the interface at the ATM switch. The TN2305/TN2306 circuit pack requires an SC connector (1 adapter is included in the Fiber Pass-Through Kit).

5.For network duplication; required for systems supporting PRI, BRI, or ASAI.

To test the synchronization splitters, you need the following equipment:

Phoenix 1541C Test Set with accessory cord kit

Phoenix 5575A T1 Test Set with cord kit or equivalent

700A DS1 CPE Loopback Jack1 (comcode 10798867)

103A block

1541CC cable kit

1.See DEFINITY ECS Release 8 Maintenance for R8r, Chapter 6, DS1 Loopback Test for more information.