DEFINITY ECS Release 8.2 ATM Installation,

Issue 1

Upgrades, and Administration 555-233-124

April 2000

 

 

1Preparing for Installation and Upgrades

Review Configuration and Equipment

1-4

Required Hardware

Table 1-1 lists the required equipment for standard, high, critical reliability, and

ATM network duplication configurations.

Table 1-1. Minimum required equipment for Release 8 ATM-PNC configurations

 

 

 

 

Reliability level

 

 

 

 

 

 

Critical/ATM

 

 

Equipment

Standard

High

Network Duplication

 

 

 

 

 

 

 

 

 

ATM switch

1

1

 

2

 

 

 

 

 

 

 

 

TN2305/TN2306 ATM interface1

1

12

2

 

 

for each PN

 

 

 

 

 

 

 

 

 

 

 

 

 

T1 or E1 synchronization splitter3

1

1

 

1

 

 

SC-connected fiber optic cable4

1

2

(PPN)

2

 

 

 

 

1

(each EPN)

 

 

 

 

 

 

 

 

 

 

TN771 maintenance/test circuit

 

 

 

1

 

 

pack5

 

 

 

 

 

 

 

 

 

 

 

 

1.TN2305 (multimode fiber); TN2306 (single-mode fiber) for Release 8 ATM-PNC.

2.High reliability requires 2 ATM-EI circuit packs in the PPN and 1 ATM-EI in each EPN.

3.The number and uses of the synchronization splitter depend on the configuration and the source(s) from which primary and secondary synchronization is derived. You may need 1 sync splitter per ATM switch. DS1 synchronization requires either no sync splitter or up to a number twice the number of sites.

4.Existing fiber optic cable may require an ST-to-SC adapter, depending on the interface at the ATM switch. The TN2305/TN2306 circuit pack requires an SC connector (1 adapter is included in the Fiber Pass-Through Kit).

5.For network duplication; required for systems supporting PRI, BRI, or ASAI.

To test the synchronization splitters, you need the following equipment:

■Phoenix 1541C Test Set with accessory cord kit

■Phoenix 5575A T1 Test Set with cord kit or equivalent

■700A DS1 CPE Loopback Jack1 (comcode 10798867)

■103A block

■1541CC cable kit

1.See DEFINITY ECS Release 8 Maintenance for R8r, Chapter 6, DS1 Loopback Test for more information.