Lucent Technologies Comcode 108678723 manual Type change system-parameters country-option s

Models: Comcode 108678723

1 230
Download 230 pages 18.93 Kb
Page 130
Image 130

DEFINITY ECS Release 8.2 ATM Installation,

Issue 1

Upgrades, and Administration 555-233-124

April 2000

 

 

5Administering ATM-PNC and ATM-CES

 

Administering DEFINITY ECS

 

5-32

Table 5-12. Gain/loss adjustment procedure

 

 

 

 

 

 

Step

Action

Description

 

 

 

 

 

 

1.

Set or verify gain/loss

Type change system-parameters country-options and

 

 

administration

press Enter.

 

 

 

The System Parameters Country-Options screen displays

 

 

 

(Table 5-16).

 

 

 

 

 

 

2.

Set digital loss plan

Domestic: Ensure that the Digital Loss Plan field is 1.

 

 

 

If it is, exit this procedure.

 

 

 

International: If the Digital Loss Plan field is anything

 

 

 

other than 1, you must change the terminal parameters.

 

 

 

Proceed to step 3.

 

 

 

 

 

 

3.

Customize the digital

Type change terminal-parameters termtype and press

 

 

phone series

Enter. (termtype can be 603/302B1, 6400 or 8400.)

 

 

administration

See the 6400-Type Terminal Parameters example (Table

 

 

 

 

 

 

5-17) display (6400 used for this example).

 

 

 

Change the Default Parameter Set field to 1.

 

 

 

 

 

 

4.

Change the settings

In the Primary Levels part of the screen, change the

 

 

 

following fields to these settings:

 

 

 

Voice Transmit (dB) = +2.5

 

 

 

Voice Receive (dB) = -2.0

For 6400 and 8400 series phones only: in the BUILT-IN SPEAKER LEVELS part of the screen, change the following fields to these settings:

Voice Transmit (dB) = 0.0

Voice receive (dB) = 0.0

Press Enter.

5.If both series 6400 and 8400 digital phones are used

Repeat steps 3 and 4 for all of the applicable phone series connected to this switch, using 603/302B1, 6400 or 8400 at the end of the command string. When finished, press Enter to effect the changes.

Page 130
Image 130
Lucent Technologies Comcode 108678723 manual Type change system-parameters country-option s