Lucent Technologies Comcode 108678723 manual Cydaatm3 KLC

Models: Comcode 108678723

1 230
Download 230 pages 18.93 Kb
Page 49
Image 49

DEFINITY ECS Release 8.2 ATM Installation,

Issue 1

Upgrades, and Administration 555-233-124

April 2000

 

 

3Installing a DEFINITY ECS ATM-PNC

Synchronization Installation and Testing

3-13

 

 

 

1

 

 

 

3

 

2

 

 

 

4

 

7

6

8

 

5

 

 

cydaatm3 KLC 020200

Figure Notes:

1.Public switched telephone network (PSTN)

2.Main distribution frame (MDF) or smart jack

3.H600-383 quad cable

4.401A T1 (100 Ω) splitter,

402A E1 (120 Ω) splitter, or

403A E1 (75 Ω) splitter connected to DEFINITY ECS

5.H600-383 quad cable from sync splitter to ATM switch A

6.H600-383 quad cable from sync splitter to duplicated ATM switch B (critical reliability/ATM network duplication)

7.Lucent ATM switch A

8.Lucent ATM switch B (critical reliability/ATM network duplication)

Figure 3-8. Synchronization connections directly to timing source (401A/402A/403A)

Page 49
Image 49
Lucent Technologies Comcode 108678723 manual Cydaatm3 KLC