Lucent Technologies Comcode 108678723 The 120A Icsu test procedure, Action Command Description

Models: Comcode 108678723

1 230
Download 230 pages 18.93 Kb
Page 58
Image 58

DEFINITY ECS Release 8.2 ATM Installation,

Issue 1

Upgrades, and Administration 555-233-124

April 2000

 

 

3Installing a DEFINITY ECS ATM-PNC

 

 

Synchronization Installation and Testing

 

3-22

Table 3-9. Installing the splitter through an ICSU —

 

 

 

 

 

 

 

 

Step

Action

Command

Description

 

 

 

 

 

 

 

 

15.

Run report

list

Wait 15 minutes before entering the command.

 

 

 

 

measurements

If the DS1 circuit pack is not error-free, refer to

 

 

 

 

ds1 summary

 

 

 

 

‘‘Troubleshooting synchronization (400A only)’’ on page

 

 

 

 

UUCSS

 

 

 

 

6-17.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

16.

Replace

 

After testing is complete, remove the modular RJ45

 

 

 

connections

 

opening plugs from port J1 and J2 of the splitter, and

 

 

 

 

 

reconnect the cables to the port(s).

 

 

 

 

 

 

 

 

17.

Test the ICSU

 

Depending on the ICSU model, go to the appropriate

 

 

 

 

 

section:

 

 

 

 

 

Testing the 120A ICSU (Table 3-10)

 

 

 

 

 

Testing the 120A 2 ICSU (Table 3-11)

 

 

 

 

 

 

 

 

Test the 120A ICSU with either a 700A DS1 CPE loopback jack or a 103A block.

Use the procedure in Table 3-10 to test a splitter connected through an ICSU.

Table 3-10. The 120A ICSU test procedure

Step

Action

Command

Description

 

 

 

 

 

 

1.

Connect 103A

 

If the 700A DS1 CPE Loopback Jack is not installed or if

 

 

block if

 

the ICSU is not a 120A:

 

 

necessary

 

Connect a 103A block at the Smart Jack end of the

 

 

 

 

 

 

 

 

H600-383 cable.

 

 

 

 

On the 103A block, strap pin1 to pin 3 and pin 2 to

 

 

 

 

pin 4, which provides a loopback to the ICSU.1

 

2.

Test the DS1

test board UUCSS

Test the DS1 circuit pack.

 

 

circuit pack

 

If any one of Tests 138 through 145 fails, follow the repair

 

 

 

 

 

 

 

 

procedures listed in DEFINITY ECS Maintenance for R8r

 

 

 

 

 

 

3.

Clear the error

clear

Clear the error events counters.

 

 

events

measurements

 

 

 

counters

ds1

 

 

 

 

esf-error-events

 

 

 

 

UUCSS

 

 

 

 

 

 

4.

Run report

list measurements

 

 

ds1 summary

 

 

UUCSS

Wait 15 minutes before entering the command.

To interpret the results, refer to Table 3-6.

If the DS1 circuit pack is not error-free, refer to ‘‘Troubleshooting synchronization (400A only)’’ on page 6-17.

5.

Remove the

Remove the 103A block from Step 1.

 

103A block

 

 

 

 

Page 58
Image 58
Lucent Technologies Comcode 108678723 manual The 120A Icsu test procedure, Action Command Description