6 Troubleshooting

 

Troubleshooting ATM-PNC

6-21

 

 

Troubleshooting synchronization (401A/402A/403A)

To troubleshoot 401A/402A/403A synchronization problems, follow the procedures in Table 6-9.

Table 6-9. Troubleshooting 401A/402A/403A synchronization

Step

Action

Description

 

 

 

 

 

1.

Check all connections

If the LEDs on the DS1 circuit pack indicate an error

 

 

 

condition, or any of the tests associated with testing the

 

 

 

DS1 circuit pack fails, recheck all cables, connectors, and

 

 

 

the splitter connection to the back of the DS1 circuit pack.

 

 

 

 

 

2.

Test the circuit pack

Test the circuit pack (test board UUCSS).

 

 

 

If the tests pass, go to step 13 (release). If a test fails,

 

 

 

continue with step 3.

 

 

 

 

 

3.

Reseat circuit pack

Reseat the DS1 circuit pack.

 

 

 

 

 

4.

Retest the circuit

Repeat the test (test board UUCSS).

 

 

pack

If Tests 138 through 145 pass, go to step 13 (release).

 

 

 

 

 

 

If any test fails, go to step 5.

 

 

 

 

 

5.

Busyout the DS1

To suppress alarms on the DS1 circuit pack, type busyout

 

 

circuit pack

board UUCSS and press Enter.

 

 

 

 

 

6.

Remove splitter

Remove the splitter from the DS1 circuit pack.

 

 

 

 

 

7.

Connect cable

Reconnect the cable directly to the back of the DS1 circuit

 

 

directly on DS1 circuit

pack (without the splitter) and reseat the DS1 circuit pack.

 

 

pack

After approximately 30 seconds the DS1 Status LEDs

 

 

 

 

 

 

should extinguish, leaving only the green Status 3 LED on

 

 

 

steady.

 

 

 

 

 

8.

Test the circuit pack

Test the circuit pack (test board UUCSS) and verify that

 

 

 

the DS1 circuit pack passes Tests 138 through 145.

 

 

 

If any one of Test 138 through 145 fails, follow the repair

 

 

 

procedures listed in DEFINITY ECS Maintenance for R8r.

 

 

 

 

 

9.

Replace splitter

If the tests pass, replace the splitter onto the back of the

 

 

 

DS1 circuit pack.

 

 

 

 

 

10.

Reseat the circuit

Reseat the DS1 circuit pack and check the Amphenol

 

 

pack

connectors, making sure they are seated properly.

 

 

 

 

 

11.

Test the circuit pack

Test the circuit pack (test board UUCSS) and verify that

 

 

 

the DS1 circuit pack passes Tests 138 through 145.

If any one of Test 138 through 145 fails, follow the repair procedures listed in DEFINITY ECS Maintenance for R8r or replace the splitter.