DEFINITY ECS Release 8.2 ATM Installation,

Issue 1

Upgrades, and Administration 555-233-124

April 2000

 

 

5Administering ATM-PNC and ATM-CES

 

 

Administering DEFINITY ECS

5-14

Table 5-8. ATM-CES administration —

 

 

 

 

 

 

 

 

 

 

 

 

Step

Action

Description

 

 

 

 

 

 

 

 

17.

Set VCI

Set the Virtual Channel Identifier (VCI) field

 

 

 

 

(32-1023). This number must be unique among signaling

 

 

 

 

groups that share the same ATM circuit pack.

 

 

 

 

 

NOTE:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

For a direct connection (two fiber-connected CES

 

 

 

 

 

circuit packs), specify the same VCI at both ends of

 

 

 

 

 

the emulated circuit. When the CES is connected to

 

 

 

 

 

an ATM switch, the VCI specified here must match

 

 

 

 

 

the VCI used for the PVC created on the ATM switch,

 

 

 

 

 

which is typically provided by the ATM switch

 

 

 

 

 

administrator.

 

 

 

 

 

NOTE:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The Signaling Mode field is set to isdn-pri and

 

 

 

 

 

is not administrable.

 

 

 

 

 

 

 

 

18.

Set idle code

Set the Idle Code field (typically 11111111).

 

 

 

 

 

 

 

 

19.

Set interface

Set the Interface Companding field (alaw or mulaw).

 

 

 

companding

Once administered, busyout the signaling group before

 

 

 

 

changing.

 

 

 

 

 

 

 

 

20.

Set country protocol

Set the Country Protocol field (Table 5-9).

 

 

 

 

 

 

 

 

21.

Set protocol version

Set the Protocol Version field (Table 5-9).

 

 

 

 

 

 

 

 

22.

Set circuit type

Set the Circuit Type field (T1 or E1).

 

 

 

 

 

NOTE:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Both ends must be the same. It is preferable to set it

 

 

 

 

 

to E1 even in the United States, Canada, or other T1

 

 

 

 

 

countries.

 

 

 

 

 

 

 

 

23.

Set connect

Set the Connect field to pbx. Once administered, busyout

 

 

 

 

the signaling group before changing.

 

 

 

 

 

 

 

 

24.

Set interface

Set the Interface field to user at one end of the

 

 

 

 

emulated circuit and to network at the other end.

 

 

 

 

 

 

 

 

25.

Set DCP/analog

Set the DCP/Analog Bearer Capability field to

 

 

 

bearer capability

3.1 kHz.

 

 

 

 

 

 

 

 

26.

Set internetworking

Set internetworking message field to PROGress.

 

 

 

message

 

 

 

 

 

 

 

 

 

 

 

 

Page 112