Table 4-5. Upgrading ATM-PNC from Release 6.3r to Release 8r Critical reliability/ATM network duplication —

 

 

 

 

 

 

Record

More

Site-specific

÷

Step

Action

Command

Description

Time

data

info

comments

 

 

 

 

 

 

 

 

 

 

19.

Check health

status pnc

Is State of Health field for both A-

 

 

Screen 4-2

 

 

 

 

 

and B-PNCs functional?

 

 

 

 

 

 

 

 

Any alarms?

 

 

 

 

 

 

 

 

Does standby refreshed? field say

 

 

 

 

 

 

 

 

yes?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20.

PNC interchange

reset

Perform PNC interchange to make the

 

 

 

 

 

 

 

pnc-interchange

B-PNC active

 

 

 

 

 

 

 

 

 

 

 

 

 

 

21.

Check interchange

status pnc

Ensure that B-PNC is active and

 

 

 

 

 

 

 

 

A-PNC is standby.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

22.

Busyout standby

busyout

Make the A-side the standby before

 

 

 

 

 

 

PNC

pnc-standby

removing any physical connections.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

23.

Repeat steps 8

 

Repeat steps 8 through 19 (check

 

 

 

 

 

 

through 19

 

health) but use a-pnc rather than

 

 

 

 

 

 

 

 

b-pnc.

 

 

 

 

24.Proceed to step 6 in

Table 4-6.