DEFINITY ECS Release 8.2 ATM Installation,

Issue 1

Upgrades, and Administration 555-233-124

April 2000

 

 

3Installing a DEFINITY ECS ATM-PNC

 

Synchronization Installation and Testing

3-28

Table 3-14. DTE loopback testing for the 316X DSU/CSU —

 

 

 

 

 

 

Step

Action

Command

Description

 

 

 

 

 

 

4.

Continue

 

Press the button under “DLB.”

 

 

 

 

Test Started displays. The 316X is now in

 

 

 

 

DTE loopback.

 

 

 

 

 

 

5.

Test the circuit

test board

 

pack

UUCSS

At the DEFINITY management terminal.

If any one of Test 138 through 145 fails, follow the repair procedures listed in DEFINITY ECS Maintenance for R8r.

 

6.

Run error

list

Wait 15 minutes and verify that the DS1 circuit

 

 

 

report

measurements

pack is free of any errors.

 

 

 

 

ds1 summary

Use Table 3-6 to interpret the periodic list

 

 

 

 

UUCSS

 

 

 

 

measurements report.

 

 

 

 

 

 

 

 

 

 

 

 

 

7.

Terminate the

 

Press the double-up arrow button.

 

 

 

DTE loopback

 

 

 

 

 

test

 

 

 

 

 

 

 

 

 

 

8.

Go through the

 

Press the button under “test.”

 

 

 

readout steps

 

 

 

 

 

 

 

 

 

 

9.

Continue

 

Press the button under “lpbk.”

 

 

 

 

 

 

 

 

10.

Continue

 

Press the button under “abort.”

 

 

 

 

 

 

 

 

11.

Continue

 

Press the button under “all.”

 

 

 

 

 

 

 

 

12.

Continue test

 

If all tests pass, and the splitter, cabling, and

 

 

 

procedure

 

316X CSU or DSU/CSU are working properly,

 

 

 

 

 

go to the ‘‘RLB loopback procedure’’ on page

 

 

 

 

 

3-28.

 

 

 

 

 

 

 

RLB loopback procedure . To start the RLB loopback testing at the 316X CSU or DSU/CSU, use the procedures in Table 3-15.

Table 3-15. RLB loopback testing for the 316X DSU/CSU

 

Step

Action

Command

Description

 

 

 

 

 

 

 

 

 

 

1.

Start the test.

 

Press the double-up arrow button.

 

 

 

 

 

 

 

 

 

 

2.

Go through the

 

Press the button under “Test.”

 

 

 

 

readout steps

 

 

 

 

 

 

 

 

 

 

 

 

3.

Continue

 

Press the button under “Lpbk.”

 

 

 

 

 

 

 

 