Installing 401A, 402A, or 403A splitters

To install a 401A, 402A, or 403A sync splitter between the network and a DS1 circuit pack, follow the procedures listed in Table 3-16.

Table 3-16. Splitter installation to DS1 (401A/402A/403A)

 

Step

Action

Command

Description

 

 

 

 

 

 

 

 

1.

Disable

disable

Prevent the system from switching

 

 

 

synchronization

synchronization

synchronization sources.

 

 

 

switch

-switch

 

 

 

 

 

 

 

 

 

 

2.

Busyout DS1

busyout board

Busyout the designated DS1 circuit pack.

 

 

 

circuit pack

UUCSS

 

 

 

 

 

 

 

 

 

 

3.

Administer

change DS1

Administer the sync splitter.

 

 

 

sync splitter

UUCSS

For T1, set the Near-end CSU Type: field

 

 

 

 

 

to integrated (see Screen 3-1).

 

 

 

 

 

For E1, set the E1 Sync-Splitter?field to

 

 

 

 

 

y (see Screen 3-2).

 

 

 

 

 

 

 

 

4.

Remove cable

 

Remove the cable from the amphenol

 

 

 

from DS1

 

connector located on rear of the DS1 circuit

 

 

 

circuit pack

 

pack.

 

 

 

 

 

 

 

 

5.

Attach the

 

Plug the splitter into the same connector just

 

 

 

splitter

 

vacated by the cable.

 

 

 

 

 

 

 

 

6.

Reconnect the

 

Plug the cable into the connector on the splitter.

 

 

 

cable

 

 

 

 

 

 

 

 

 

 

 

7.

Secure the

 

Secure the splitter to the carrier using the large

 

 

 

splitter

 

mounting strap removed from a fiber

 

 

 

 

 

transceiver.

 

 

 

 

 

 

 

 

8.

Check

 

Check that the Amphenol connection is secure.

 

 

 

connection

 

 

 

 

 

 

 

 

 

 

 

9.

Reseat DS1

 

Release the clip holding the DS1 circuit pack,

 

 

 

circuit pack

 

pull out slightly, close clip.

 

 

 

 

 

 

 

 

10.

Release DS1

release board

Restore the designated DS1 circuit pack to

 

 

 

circuit pack

UUCSS

service.

 

 

 

 

 

 

 