6 Troubleshooting

 

Troubleshooting ATM-PNC

6-19

 

 

Connected through a DSU/CSU

To troubleshoot synchronization problems in systems where the synchronization signal connects through a Data Service Unit (DSU) or Channel Service Unit (CSU), follow the procedures in Table 6-8.

Use this table if the

DTE or RLB loopback tests fail

CSU or DSU/CSU does not return to normal service

Table 6-8. Troubleshooting 400A T1 synchronization (through a DSU/CSU)

Step

Action

Description

 

 

 

 

1.If DSU/CSU does not go back to normal operation

Verify that the current line compensation settings on the DS1 circuit pack (change board) match the DTE equalization settings of the CSU or DSU/CSU for the length of cable:

 

2.

Go through readout

On the 316X CSU or DSU/CSU, press the double-up arrow.

 

 

steps

 

 

 

 

 

 

 

3.

Continue

Press the button under the “Config” readout

 

 

 

 

 

4.

Continue

Press the button under the “Activ.” readout

 

 

 

 

 

5.

Continue

Press the button under the “Edit.” readout

 

 

 

 

 

6.

Continue

Press the button under the “DTE.” readout

 

 

 

 

 

7.

Continue

Press the button under the “Next” readout until

 

 

 

“Equalization” displays. The top line of the display shows

 

 

 

the current settings.

 

 

 

 

 

8.

Verify settings

If these settings do not agree with the DS1 administration

 

 

 

(step 1), enter the correct settings and retest.

 

 

 

If the test still fails, continue.

 

 

 

 

 

9.

Increase equalization

Increase the equalization settings on the CSU or DSU/CSU

 

 

settings

by one value.

 

 

 

 

 

10.

Go through readout

Press the right-arrow button until “Value” displays. For

 

 

steps

example, if 0 through 133 displays, go to 133 through 266,

 

 

 

and so on.

 

 

 

 

 

11.

Continue

Press the double-up arrow.

 

 

 

 

 

12.

Continue

Press the button under the “Yes” readout when asked to

 

 

 

save options.

 

 

 

 

 

13.

Continue

Press the button under the “Active” readout when asked

 

 

 

where to save the options.

 

 

 

“Command Complete” displays.

 

 

 

 

 

14.

Retest

Retest

 

 

 

 

 