Lucent Technologies Comcode 108678723 manual See ‘‘DEFINITY ECS configurations’’ on page 1-6 for

Models: Comcode 108678723

1 230
Download 230 pages 18.93 Kb
Page 38
Image 38

DEFINITY ECS Release 8.2 ATM Installation,

Issue 1

Upgrades, and Administration 555-233-124

April 2000

 

 

3Installing a DEFINITY ECS ATM-PNC

Equipment Installation

3-2

Slot restrictions for an ATM interface circuit packs are similar to expansion interface circuit packs:

PPN: ATM interface circuit packs used for ATM-PNC must occupy the slots labeled EXPANSION INTERFACE.

EPNs: ATM interface circuit packs used for ATM-PNC can occupy slot 1 (and 2 if duplicated) on carrier A, and slot 2 (and 3 if duplicated) on carrier

B

Follow the steps in Table 3-1 to ensure that

the applicable equipment is installed correctly.

the customer’s configuration is properly recorded (use worksheet in Appendix A, ‘‘Baselining the Customer’s Configuration)’’.

Table 3-1. General installation process

Step

Action

Description

 

 

 

 

 

1.

Install DEFINITY ECS

Refer to the appropriate installation book

 

 

switch

See ‘‘DEFINITY ECS configurations’’ on page 1-6for

 

 

 

 

 

 

connection schematics.

 

 

 

 

 

2.

Install ATM switch(es)

Refer to your ATM switch’s quick reference guide.

 

 

or access

 

 

 

concentrators

 

 

 

 

 

3.Check the distances from the ATM switch to the DS1 timing source

Use the information in Table 3-3 to determine the maximum cable run lengths for the configuration for more information.

4.

Install ATM interface

Insert the TN2305/TN2306 circuit pack(s) into the

 

circuit pack

appropriate slot(s).

 

 

 

5.

Route the fiber optic

Follow the fiber pass-through procedure in the appropriate

 

cables between the

installation book.

 

ATM switch and the

 

 

 

DEFINITY PPN and

! WARNING:

 

EPNs.

 

 

Be sure that the fiber optic cable is secured so that

 

 

 

 

 

 

the door of the DEFINITY ECS switch does not pinch

 

 

 

or bend the cable.

 

 

 

6.

Connect the fiber

Connect the fiber optic cables to the ATM switch.

 

optic cables

 

 

 

 

 

NOTE:

 

 

 

If the installation uses the customer’s existing fiber, you may need an ST-to-SC adapter (1 included in Fiber Pass-Through Kit).

Page 38
Image 38
Lucent Technologies Comcode 108678723 manual See ‘‘DEFINITY ECS configurations’’ on page 1-6 for