6Troubleshooting

 

 

Troubleshooting ATM-PNC

6-22

Table 6-9. Troubleshooting 401A/402A/403A synchronization —

 

 

 

 

 

 

 

 

Step

Action

Description

 

 

 

 

 

 

 

 

12.

Escalate if necessary

If the DS1 circuit pack tests OK, go to step 13.

 

 

 

 

If step 11 still fails, escalate to Tier 3 or replace the splitter.

 

 

 

 

 

 

 

 

13.

Release the circuit

Release the DS1 circuit pack (release board UUCSS).

 

 

 

pack

 

 

 

 

 

 

 

 

 

 

 

14.

Verify active

Verify that the designated DS1 circuit pack is now the

 

 

 

synchronization

active sync source (status synchronization).

 

 

 

source

 

 

 

 

 

 

 

 

 

 

Troubleshooting interoperability

This section covers the following ATM interoperability topics:

Physical connections—Checks for correct ATM installation and configuration

Administration—Checks for correct DEFINITY ECS and ATM switch administration

TN2305/TN2306 circuit pack—Checks LED status, circuit pack insertion, and demand tests

ATM signaling architecture—Checks the interoperability between the DEFINITY ECS switch and the ATM switch

Because Lucent offers a variety of ATM switches, this discussion suggests general rather than specific diagnostics.

Physical connections

Has the ATM switch been installed and configured correctly?

Diagnostics

Is the ATM switch powered up?

If you are administering the ATM switch through a locally attached console, is there a local console terminal connected to the console port on the ATM switch processor circuit pack with the correctly pinned RS232 serial cable?

If you are administering the ATM switch through telnet over the Ethernet, is there an Ethernet drop plugged into the Ethernet port on the ATM switch processor board? (Note that a few ATM switch commands are only permitted over the local console terminal.)