DEFINITY ECS Release 8.2 ATM Installation,

Issue 1

Upgrades, and Administration 555-233-124

April 2000

3 Installing a DEFINITY ECS ATM-PNC

 

 

Synchronization Installation and Testing

3-9

 

 

 

 

 

 

 

 

5

4

6

1

 

 

 

 

 

 

 

T

X

 

 

 

 

 

 

 

 

 

 

 

 

 

R

X

 

 

O

R

K

 

 

 

 

 

 

 

 

 

 

 

 

W

 

 

 

 

 

 

 

 

E

T

 

 

 

 

 

 

 

N

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Technologies

 

 

 

 

Lucent

 

 

 

 

 

 

 

 

 

 

 

403A

 

 

 

 

108508102E1

020300

 

 

OHM

 

 

 

 

75

 

SPLITTER

TODEFINITY

SYNC

 

 

 

 

 

 

 

 

crda403a KLC

 

 

 

 

 

 

 

 

 

 

 

 

 

W

IT

 

 

S

 

 

AT

M

 

6

 

 

 

TO

 

 

 

 

 

 

 

3

2

Figure Notes:

1.

Amphenol connector to DEFINITY

4.

Network receive connection, BNC

 

ECS

 

connector

2.

Synchronization source (timing

5.

Network transmit connection, BNC

 

output ports) to ATM switch1

 

connector

3.

Synchronization source (timing

6.

Jumpers and capacitors (inside case).

 

output ports) to ATM switch1

 

See Figure 3-5 for settings.

1.These are identical DS1 timing source signals to the ATM switches. The ATM switch can use two separate DS1 timing signals (one at a time from two separate spans).

Figure 3-4. 403A synchronization splitter