3 Installing a DEFINITY ECS ATM-PNC

 

Synchronization Installation and Testing

3-25

 

 

To configure the 316X CSU to send an AIS blue alarm, use the procedures in

Table 3-12.

Table 3-12. Configuring the 316X CSU to send AIS blue alarm

 

Step

Action

Description

 

 

 

 

 

 

 

 

 

1.

Configure CSU

At the 316X CSU press the double-up arrow

 

 

 

 

 

 

 

 

 

2.

Go through the

Press the button under “Cnfig.”

 

 

 

 

readout steps

 

 

 

 

 

 

 

 

 

 

3.

Continue

Press the button under “Activ.”

 

 

 

 

 

 

 

 

 

4.

Continue

Press the button under “Edit.”

 

 

 

 

 

 

 

 

 

5.

Continue

Press the right arrow until “GEN” displays.

 

 

 

 

 

 

 

 

 

6.

Continue

Press the button under “GEN.”

 

 

 

 

 

 

 

 

 

7.

Continue

Press F1 (“Next”) until “Gen Yellow Alarm” displays. (This

 

 

 

 

 

option defaults as enabled.)

 

 

 

 

 

 

 

 

 

8.

Continue

Press the button under “Disabled.”

 

 

 

 

 

 

 

 

 

9.

Continue

Press the double-up arrow.

 

 

 

 

 

Save Option displays when “Enabled” changes to

 

 

 

 

 

“Disabled.”

 

 

 

 

 

 

 

 

 

10.

Save settings

Press the button under the word “Yes” at the “Save

 

 

 

 

 

Options Yes or No” prompt. Otherwise press F1 twice.

 

 

 

 

 

 

 

 

 

11.

Save options

Press the button under “Activ” when asked where to save

 

 

 

 

 

the options.

 

 

 

 

 

Command Complete displays.

 

 

 

 

 

 

 

 

 

12.

Return to default

The CSU times out to its default ESF CSU Operational

 

 

 

 

screen

screen or set it there by pressing the double-up arrow

 

 

 

 

 

once and then pressing F1 twice.

 

 

 

 

 

 

 

 

 

13.

Install the splitter

Go to Table 3-13 to install the splitter.

 

 

 

 

 

 

 

NOTE:

All four faceplate status LEDs on the DS1 circuit pack are dark (not lit) when using an external CSU or DSU/CSU. The STATUS LEDs on the DS1 circuit pack are only functional with a 120A ICSU.